Electromagnets Under the Table: an Unobtrusive Magnetic Navigation System for Microsurgery

Adam Schonewille,Changyan He,Cameron Forbrigger,Nancy Wu,James Drake,Thomas Looi,Eric Diller
2023-08-24
Abstract:Miniature magnetic tools have the potential to enable minimally invasive surgical techniques to be applied to space-restricted surgical procedures in areas such as neurosurgery. However, typical magnetic navigation systems, which create the magnetic fields to drive such tools, either cannot generate large enough fields, or surround the patient in a way that obstructs surgeon access to the patient. This paper introduces the design of a magnetic navigation system with eight electromagnets arranged completely under the operating table, to endow the system with maximal workspace accessibility, which allows the patient to lie down on the top surface of the system without any constraints. The found optimal geometric layout of the electromagnets maximizes the field strength and uniformity over a reasonable neurosurgical operating volume. The system can generate non-uniform magnetic fields up to 38 mT along the x and y axes and 47 mT along the z axis at a working distance of 120 mm away from the actuation system workbench, deep enough to deploy magnetic microsurgical tools in the brain. The forces which can be exerted on millimeter-scale magnets used in prototype neurosurgical tools are validated experimentally. Due to its large workspace, this system could be used to control milli-robots in a variety of surgical applications.
Robotics
What problem does this paper attempt to address?
The paper aims to address the application of micro-magnetic tools in space-constrained surgeries, such as neurosurgery. Traditional magnetic navigation systems either fail to generate a sufficiently strong magnetic field or obstruct the doctor's access to the patient. Therefore, the paper proposes a new magnetic navigation system design by arranging eight electromagnets entirely beneath the operating table, thereby achieving maximum workspace accessibility. This design allows the patient to lie flat on top of the system without any restrictions, and the optimized geometric layout of the electromagnets maximizes the magnetic field strength and uniformity within a reasonable neurosurgical volume. The system can generate a non-uniform magnetic field of up to 38 millitesla (mT) along the x-axis and y-axis, and 47 millitesla along the z-axis at a distance of 120 millimeters from the operating platform, sufficient for deploying magnetic microsurgical tools in the brain. Additionally, the system has been experimentally validated for the forces it can exert on millimeter-scale magnets used in prototype neurosurgical tools. Due to its large workspace, the system can be used to control micro-robots in various surgical applications.