Fundamental sensitivity limit of lossy cavity-enhanced interferometers with external and internal squeezing

Mikhail Korobko,Jan Südbeck,Sebastian Steinlechner,Roman Schnabel
DOI: https://doi.org/10.1103/PhysRevA.108.063705
2023-07-18
Abstract:Quantum optical sensors are ubiquitous in various fields of research, from biological or medical sensors to large-scale experiments searching for dark matter or gravitational waves. Gravitational-wave detectors have been very successful in implementing cavities and quantum squeezed light for enhancing sensitivity to signals from black hole or neutron star mergers. However, the sensitivity to weak forces is limited by available energy and optical decoherence in the system. Here, we derive the fundamental sensitivity limit of cavity and squeezed-light enhanced interferometers with optical loss.This limit is attained by the optimal use of an additional internal squeeze operation, which allows to mitigate readout loss. We demonstrate the application of internal squeezing to various scenarios and confirm that it indeed allows to reach the best sensitivity in cavity and squeezed-light enhanced linear force sensors. Our work establishes the groundwork for the future development of optimal sensors in real-world scenarios where, up until now, the application of squeezed light was curtailed by various sources of decoherence.
Quantum Physics,General Relativity and Quantum Cosmology
What problem does this paper attempt to address?
### Problems the Paper Attempts to Solve This paper aims to explore the fundamental sensitivity limits of cavity-enhanced interferometers with optical losses under the influence of external and internal squeezed light. Specifically, the authors attempt to address the following issues: 1. **How to overcome the impact of optical losses on the sensitivity of quantum squeezed light-enhanced sensors**: - Optical losses (including injection loss, readout loss, and internal loss) can weaken the effect of quantum squeezed light, thereby limiting the sensor's sensitivity. - The authors propose mitigating readout loss by introducing internal squeezing operations, thus improving the overall sensitivity of the sensor. 2. **Determining the fundamental sensitivity limit of cavity-enhanced interferometers**: - The authors derive the fundamental sensitivity limit of cavity-enhanced interferometers with optical losses and demonstrate how to achieve this limit through optimal internal squeezing operations. - This limit is determined by internal losses, while readout losses can be alleviated through internal squeezing. 3. **Comparison between internal squeezing and output amplification**: - The authors compare the effects of internal squeezing and ideal output amplification on sensor performance, exploring the advantages and disadvantages of both under different loss conditions. - The results show that in the presence of input, internal, and readout losses, combining internal squeezing and output amplification can achieve optimal sensitivity. 4. **Optimized design for practical applications**: - The authors propose an optimized design scheme that combines internal squeezing and output amplification to address the three main sources of loss commonly encountered in practical applications. - This scheme is particularly suitable for high-precision sensors such as gravitational wave detectors, where readout losses mainly occur in components like Faraday isolators, mode matching, and mode cleaners. ### Main Contributions - **Theoretical Derivation**: The authors provide a detailed derivation of the fundamental sensitivity limit of cavity-enhanced interferometers with optical losses and demonstrate how internal squeezing can mitigate readout losses. - **Experimental Validation**: The authors experimentally validate the effect of internal squeezing on mitigating readout losses, further supporting their theoretical analysis. - **Practical Application**: The authors propose an optimized design scheme that combines internal squeezing and output amplification, providing a theoretical foundation and practical guidance for the design of future high-precision sensors. ### Conclusion Through theoretical analysis and experimental validation, this paper demonstrates the potential of internal squeezing in overcoming optical losses and improving sensor sensitivity. The research results not only provide new insights for the design of high-precision sensors such as gravitational wave detectors but also lay the foundation for the development of quantum sensing technology in other fields.