Uniform error bound for PCA matrix denoising

Xin T. Tong,Wanjie Wang,Yuguan Wang
2024-08-28
Abstract:Principal component analysis (PCA) is a simple and popular tool for processing high-dimensional data. We investigate its effectiveness for matrix denoising. We consider the clean data are generated from a low-dimensional subspace, but masked by independent high-dimensional sub-Gaussian noises with standard deviation $\sigma$. Under the low-rank assumption on the clean data with a mild spectral gap assumption, we prove that the distance between each pair of PCA-denoised data point and the clean data point is uniformly bounded by $O(\sigma \log n)$. To illustrate the spectral gap assumption, we show it can be satisfied when the clean data are independently generated with a non-degenerate covariance matrix. We then provide a general lower bound for the error of the denoised data matrix, which indicates PCA denoising gives a uniform error bound that is rate-optimal. Furthermore, we examine how the error bound impacts downstream applications such as clustering and manifold learning. Numerical results validate our theoretical findings and reveal the importance of the uniform error.
Statistics Theory,Methodology
What problem does this paper attempt to address?
### Problem the Paper Attempts to Solve The paper "Uniform error bound for PCA matrix denoising" aims to address the effectiveness of Principal Component Analysis (PCA) in matrix denoising. Specifically, the authors focus on how to effectively remove noise from high-dimensional data using PCA and ensure that the distance between the denoised data points and the original clean data points is uniformly bounded across all samples. ### Background and Motivation In modern data science, data is often referred to as the "new gold." The abundance of data and the ever-evolving statistical methods provide us with powerful tools to extract valuable information and interpret scientific problems. However, noise is inevitably introduced during data collection, posing significant challenges to data analysis. Particularly in high-dimensional data, each dimension's data points are affected by noise, and as the dimensions increase, the overall noise also increases, exacerbating the "curse of dimensionality" problem. ### Research Question The main research question of the paper is to evaluate the accuracy of PCA denoising estimates, i.e., the distance between the estimated value \(\hat{X}_i\) and the true value \(X_i\). Most existing theoretical analyses focus on the Frobenius distance between matrices \(\hat{X}\) and \(X\), while this paper aims to obtain a uniform error bound across all data points, allowing for individual statistical analysis of each sample. Specifically, the authors aim to establish the following \(\ell_2 \to \ell_\infty\) or uniform error bound: \[ \|\hat{X} - X\|_{2,\infty} := \max_{a \in \mathbb{R}^d, a \neq 0} \frac{\|(\hat{X} - X)a\|_\infty}{\|a\|_2} = \max_{i \in [n]} \|X_i - \hat{X}_i\| = O(\sigma \log n) \] where \(d = cn\), \(c\) and \(\sigma\) are some absolute constants. Here, \(O(\cdot)\) indicates a possible dependence on a low-dimensional factor \(r\). ### Main Contributions 1. **General Form of Error Bound**: In Section 2.1, Theorem 1 establishes a general form of the error bound for any \(d\) and \(\sigma\). When assuming \(n \asymp d\) and the \(r\)-th largest singular value of \(X\), \(\lambda_r(X) \geq c_X \sqrt{n}\), the precision of the error bound is proven. The result does not depend on the correlation structure of the clean data \(X_i\). 2. **Sufficient Conditions**: In Section 2.3, sufficient conditions for the assumption \(\lambda_r(X) \geq c_X \sqrt{n}\) are discussed. Using random matrix theory, it is proven that the covariance matrix of \(X\) having a non-zero \(r\)-th eigenvalue satisfies this assumption. An example inspired by spatiotemporal datasets, the sawtooth line example, is provided for illustration. 3. **Lower Bound on Signal-to-Noise Ratio and Sample Size**: Section 3 provides a general lower bound on the signal-to-noise ratio and sample size \(n\) to ensure that the average error does not exceed any constant \(\epsilon > 0\). The lower bound indicates that PCA denoising has optimal requirements for signal-to-noise ratio and sample size. 4. **Practical Impact on Downstream Applications**: Section 4 demonstrates the practical impact of the uniform error bound \(\|\hat{X} - X\|_{2,\infty}\) on various downstream applications. Assuming \(\|\hat{X} - X\|_{2,\infty} \leq \epsilon\), performance guarantees for applications such as clustering and manifold learning are provided. 5. **Numerical Simulations**: Section 5 supports the theoretical findings through numerical simulations. A clustering task involving high-dimensional data sampled from two separate sawtooth lines is considered. For these data, PCA denoising achieves the uniform error bound, making spectral clustering more efficient. It is also shown that data with small "average error" is insufficient to ensure the same level of performance.