A Prototype Scintillator Real-Time Beam Monitor for Ultra-high Dose Rate Radiotherapy

Daniel S. Levin,Peter S. Friedman,Claudio Ferretti,Nicholas Ristow,Monica Tecchio,Dale W. Litzenberg,Vladimir Bashkirov,Reinhard Schulte
DOI: https://doi.org/10.1002/mp.17018
2024-03-09
Abstract:FLASH Radiotherapy (RT) is a potentially new cancer radiotherapy technique where an entire therapeutic dose is delivered in about 0.1 s and at ~1000 times higher dose rate than in conventional RT. For clinical trials to be conducted safely, precise and fast beam monitoring that can generate an out-of-tolerance beam interrupt is required. A FLASH Beam Scintillator Monitor (FBSM) is being developed based in part on a novel proprietary inorganic hybrid scintillator material. The FBSM provides large area coverage, low mass profile, linear response over a broad dynamic range, radiation tolerance, and real-time analysis IEC-compliant fast beam-interrupt signal. This paper includes the design concept and test results from a prototype device in radiation beams that include heavy ions, FLASH level dose per pulse electron beams, anda hospital radiotherapy clinic with electron beams. Results include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. The scintillator showed a small -0.02%/kGy signal decrease after a 212 kGy cumulative dose resulting from continuous exposure for 15 minutes at a FLASH compatible dose rate of 234 Gy/s. These tests established the linear response of the FBSM with respect to dose per pulse. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile. At 20 kfps or 50 microsec/frame, the real-time FPGA based computation and analysis of beam position, beam shape, and beam dose takes < 1 microsec.
Medical Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to achieve accurate and rapid beam monitoring in ultra - high - dose - rate radiotherapy (FLASH Radiotherapy, RT). Since the dose rate of FLASH radiotherapy is more than 1,000 times higher than that of traditional radiotherapy, a high - precision, fast - response beam monitor capable of generating beam - interruption signals outside the tolerance range is required to ensure the safe progress of clinical trials. This article presents the design concept of a real - time beam - shape monitor (FBSM) based on a new scintillator material and the test results of its prototype, aiming to simultaneously provide functions such as large - area coverage, low - mass profile, linear response within a wide dynamic range, radiation tolerance, true two - dimensional imaging, and high spatial resolution. These functions cannot be simultaneously provided by existing conventional radiotherapy detection techniques.