Interface Self-Referenced Dynamic Full-Field Optical Coherence Tomography

Tual Monfort,Salvatore Azzollini,Tasnim Ben Yacoub,Isabelle Audo,Sacha Reichman,Kate Grieve,Olivier Thouvenin
DOI: https://doi.org/10.48550/arXiv.2302.08839
2023-02-17
Abstract:Dynamic full-field optical coherence tomography (D-FFOCT) has recently emerged as an invaluable live label-free and non-invasive imaging modality able to image subcellular biological structures and their metabolic activity within complex 3D samples. However, D-FFOCT suffers from fringe artefacts when imaging nearby reflective surfaces and is highly sensitive to vibrations. Here, we present interface Self-Referenced (iSR) D-FFOCT, an alternative configuration to D-FFOCT that takes advantage of the presence of the sample coverslip in between the sample and the objective by using it as a defocused reference arm, thus avoiding the aforementioned artefacts. We demonstrate the ability of iSR D-FFOCT to image 2D fibroblast cell cultures, which are among the flattest mammalian cells.
Optics,Biological Physics,Subcellular Processes
What problem does this paper attempt to address?
The problems that this paper attempts to solve mainly focus on several key challenges encountered in the imaging process of dynamic full - field optical coherence tomography (D - FFOCT) technology: 1. **Stripe Artifact Problem**: When using D - FFOCT to image samples close to reflective surfaces, stripe artifacts will appear, which will interfere with the image quality. Especially when imaging thin samples (such as 2D cell cultures), this effect is particularly significant. 2. **Vibration Sensitivity**: D - FFOCT is very sensitive to external vibrations at the sub - nanometer level. Even on a specially designed anti - vibration optical platform, it is difficult to completely eliminate these vibrations, thus affecting the image quality and the accurate quantification of organelle movement and metabolic contrast. 3. **Difficulties in Using High - Numerical - Aperture (NA) Objectives**: D - FFOCT faces challenges when using very high - numerical - aperture objectives. Because any asymmetry, including spherical aberration caused by small alignment errors, will lead to image distortion, loss of field of view and a decrease in interference contrast. To solve these problems, the authors propose a new interference configuration method - interface self - reference (iSR) D - FFOCT. This method uses the sample coverslip as a non - focused reference arm, thereby avoiding the above - mentioned stripe artifact problem and being insensitive to mechanical vibrations, making the imaging more stable and reliable. In addition, iSR D - FFOCT shows better performance when using high - numerical - aperture objectives and is suitable for imaging thin samples and surface structures. Through this new method, researchers can successfully image 2D fibroblast samples, demonstrating its potential application value in biological research, especially in disease modeling and rapid cell - phenotype diagnosis.