Feasibility of Ultra-low Radiation and Contrast Medium Dosage in Aortic CTA Using Deep Learning Reconstruction at 60 kVp: An Image Quality Assessment

Ke Qi,Chensi Xu,Dian Yuan,Yicun Zhang,Mengyuan Zhang,Weiting Zhang,Jiong Zhang,Bojun You,Jianbo Gao,Jie Liu
DOI: https://doi.org/10.1016/j.acra.2024.10.042
IF: 5.482
2024-11-22
Academic Radiology
Abstract:Objective To assess the viability of using ultra-low radiation and contrast medium (CM) dosage in aortic computed tomography angiography (CTA) through the application of low tube voltage (60 kVp) and a novel deep learning image reconstruction algorithm (ClearInfinity, DLIR-CI). Methods Iodine attenuation curves obtained from a phantom study informed the administration of CM protocols. Non-obese participants undergoing aortic CTA were prospectively allocated into two groups and then obtained three reconstruction groups. The conventional group (100 kVp-CV group) underwent imaging at 100 kVp and received 210 mg iodine/kg in combination with a hybrid iterative reconstruction algorithm (ClearView, HIR-CV). The experimental group was imaged at 60 kVp with 105 mg iodine/kg, while images were reconstructed with HIR-CV (60 kVp-CV group) and with DLIR-CI (60 kVp-CI group). Student's t-test was used to compare differences in CM protocol and radiation dose. One-way ANOVA compared CT attenuation, image noise, SNR, and CNR among the three reconstruction groups, while the Kruskal–Wallis H test assessed subjective image quality scores. Post hoc analysis was performed with Bonferroni correction for multiple comparisons, and consistency analysis conducted in subjective image quality assessment was measured using Cohen's kappa. Results The radiation dose (1.12 ± 0.23 mSv vs. 2.03 ± 0.82 mSv) and CM dosage (19.04 ± 3.03 mL vs. 38.11 ± 6.47 mL) provided the reduction of 45% and 50% in the experimental group compared to the conventional group. The CT attenuation, SNR, and CNR of 60 kVp-CI were superior to or equal to those of 100 kVp-CV. Compared to the 60 kVp-CV group, images in 60 kVp-CI showed higher SNR and CNR (all P < 0.001). There was no difference between the 60 kVp-CI and 100 kVp-CV group in terms of the subjective image quality of the aorta in various locations (all P > 0.05), with 60 kVp-CI images were deemed diagnostically sufficient across all vascular segments. Conclusion For non-obese patients, the combined use of 60 kVp and DLIR-CI algorithm can be preserving image quality while enabling radiation dose and contrast medium savings for aortic CTA compared to 100 kVp using HIR-CV.
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?