[Long-term results of posterior chamber phakic intraocular lens implantation for correction of high ametropia]

M Le Loir,B Cochener
DOI: https://doi.org/10.1016/j.jfo.2011.06.006
Abstract:Purpose: To assess efficacy, stability and safety of posterior chamber phakic intraocular lens implantation with STAAR Visian ICL for correction of high ametropia, with a mean follow-up of 5 years (3.5-10 years). Patients and methods: Ninety eyes of 53 highly ametropic patients (45 myopia, ten hyperopia and 35 with mixed astigmatism) were included in a retrospective single-surgeon study, using primarily the V4 ICL model (87 eyes). We studied pre- and postoperative refractive efficacy, endothelial cell density, crystalline lens opacification and intraocular clearances within the various compartments of the eye. Results: Mean uncorrected visual acuity was 0.77 at the 12th postoperative month; 17 of 90 eyes required adjunctive photoablation for residual astigmatism. Forty-eight percent of eyes gained at least one line of best corrected visual acuity. After implantation, the decrease in endothelial cell density remained stable at 0.69%/year, and 91% of eyes showed no opacification of the crystalline lens. Mean endothelium-ICL and ICL-crystalline lens distances were 2.41 mm and 0.52 mm respectively. Overall patient satisfaction achieved was 96% at 36 months postoperatively. Discussion and conclusion: These results demonstrate efficacy, stability and safety of the ICL V4 phakic IOL for the correction of high ametropia. Long-term follow-up did not show a significant increase in cataract formation in implanted eyes.