Assessment of fiducial motion in CBCT projections of the abdominal tumor using template matching and sequential stereo triangulation

Oluwaseyi M. Oderinde,Hassan Mostafavi,Daniel Simpson,James Murphy,Gwe-Ya Kim,Laura I. Cervino
DOI: https://doi.org/10.48550/arXiv.2211.05380
2022-11-10
Abstract:Purpose: To assess the fiducial motion in abdominal stereotactic body radiotherapy (SBRT) using the cone-beam computed tomography (CBCT) projections acquired for pre-treatment patient set-up. Materials and Methods: Pre-treatment CBCT projections and anterior-posterior (AP) and lateral (LAT) pair of fluoroscopic sequences of 7 pancreatic and 6 liver SBRT patients with implanted fiducials were analyzed for 49 treatment fractions retrospectively. A tracking algorithm based on template matching and sequential stereo triangulation algorithms was used to track the fiducials in the CBCT projections and the fluoro sequence pairs. We predicted the clinical couch adjustment from CBCT tracking and compared it with the clinical couch decision made during the patient's treatment. Results: In 3D coordinate, the fiducial motion ranges for pancreas cases were 9.90+/-3.52 mm, 10.65+/-5.91 mm, and 10.74+/-6.24 mm for CBCT, AP, and LAT fluoro, respectively, while in the liver, they were 13.93+/-3.39 mm, 11.17+/-3.75 mm, and 11.52+/-4.33 mm, respectively. Prediction of couch adjustment in LAT, SI, and AP coordinates from CBCT tracking agrees with the actual clinical couch correction within 0.92+/-0.74 mm, 1.37+/-1.26 mm, and 0.68+/-0.56 mm for pancreas cases and within 1.12+/-0.96 mm, 1.15+/-0.92 mm and 0.90+/-0.86 mm for liver cases, respectively. Conclusion: Tracking pre-treatment CBCT projections using template matching and sequential stereo triangulation is suitable for assessing fiducial motion and adjusting the patient setup for abdominal SBRT. CBCT can be used for motion modeling, potentially eliminating the need for additional fluoroscopic pair acquisition and thus reducing the imaging dose to the patient and the total treatment time.
Medical Physics
What problem does this paper attempt to address?
This paper aims to solve the problem of how to use cone - beam computed tomography (CBCT) projections to evaluate marker movement in abdominal stereotactic body radiotherapy (SBRT). Specifically, the research objectives are: 1. **Evaluate marker movement in CBCT projections**: Track marker movement in CBCT projections through template - matching and sequential stereo - triangulation algorithms to evaluate its application in patient positioning before treatment. 2. **Verify the accuracy of the tracking algorithm**: Conduct experiments using a motion phantom with known motion, compare the tracking results with the actual motion trajectory, and verify the accuracy of the algorithm. 3. **Evaluate the correlation between internal and external movement**: Analyze the correlation between internal target movement and external respiratory signals by CBCT and fluoroscopy. 4. **Predict clinical treatment - table adjustments**: Based on the tracking results of CBCT projections, predict clinical treatment - table adjustments before treatment and compare them with actual clinical decisions. Through these objectives, the research aims to demonstrate the potential of CBCT projections in evaluating marker movement and optimizing patient positioning before treatment, thereby reducing the need for additional fluoroscopy imaging, and decreasing the patient's imaging dose and total treatment time.