Ambient Neutron Measurement at Taishan Antineutrino Observatory

Ruhui Li,Yichen Li,Zhimin Wang,Qiang Li,Liang Zhan,Jun Cao
DOI: https://doi.org/10.48550/arXiv.2209.02035
2022-09-06
Abstract:The Taishan Antineutrino Observatory (TAO) is a ton-level liquid scintillator detector to be placed at 30\,m from a core of the Taishan Nuclear Power Plant for precise reactor antineutrino spectrum measurements. One important background for TAO physics are the interactions of ambient neutrons that can penetrate its outer shieldings. The neutrons fluence and energy spectrum are measured with a Bonner sphere spectrometer. Data is unfolded with the iterative Maximum-Likelihood Expectation-Maximization (MLEM) method. A simulation based on Geant4 is performed to provide the initial input spectrum to the unfolding and to understand the unfolded result. The total neutron fluence rate is measured to be 36.1 $\pm$ 4.7 $Hz/m^2$, which is higher than the expectation. For neutrons with kinetic energy lower than 20\,MeV, the measured fluence rate and energy spectrum can be well reproduced by simulation. While for the region greater than 20\,MeV, a significant discrepancy is observed and shall be understood with further studies.
Instrumentation and Detectors,High Energy Physics - Experiment
What problem does this paper attempt to address?