$^{22}$Na Activation Level Measurements of Fused Silica Rods in the LHC Target Absorber for Neutrals (TAN) Compared to FLUKA Simulations

S.Yang,M.Sabate Gilarte,A.Tate,N.Santiago,R.Longo,S.Mazzoni,F.Cerutti,E.Bravin,M.Grosse Perdekamp,G.Lerner,D.Prelipcean,Z.Citron,B.Cole,S.Jackobsen,M.D.Kaminski,T.Koeth,C.Lantz,D. MacLean,A. Mignerey,M.Murray,M.Palm,M.Phipps,P.Steinberg,A.Tsinganis
DOI: https://doi.org/10.1103/PhysRevAccelBeams.25.091001
2022-04-06
Abstract:The Target Absorbers for Neutrals (TANs) are located in a high-intensity radiation environment inside the tunnel of the Large Hadron Collider (LHC). TANs are positioned about $140$ m downstream from the beam interaction points. Seven $40$ cm long fused silica rods with different dopant specifications were irradiated in the TAN by the Beam RAte of Neutrals (BRAN) detector group during $p$+$p$ data taking from 2016 to 2018 at the LHC. The peak dose delivered to the fused silica rods was $18$ MGy. We report measurements of the $^{22}$Na activation of the fused silica rods carried out at the University of Illinois at Urbana-Champaign and Argonne National Laboratory. At the end of the irradiation campaign, the maximum $^{22}$Na activity observed was $A=21$ kBq$/{\rm cm^3}$ corresponding to a density, $\rho= 2.5\times 10^{12} /{\rm cm^3}$, of $^{22}$Na nuclei. FLUKA Monte Carlo simulations have been performed by the CERN FLUKA team to estimate $^{22}$Na activities for the irradiated BRAN rod samples. The simulations reproduce the $^{22}$Na activity profile measured along the rods, with a 35% underestimation of the experimental measurement results.
Accelerator Physics,Instrumentation and Detectors