Enhanced quantum sensing with room-temperature solid-state masers

Hao Wu,Shuo Yang,Mark Oxborrow,Qing Zhao,Bo Zhang,Jiangfeng Du
DOI: https://doi.org/10.48550/arXiv.2201.04298
2022-01-13
Abstract:Quantum sensing with solid-state systems finds broad applications in diverse areas ranging from material and biomedical sciences to fundamental physics. Several solid-state spin sensors have been developed, facilitating the ultra-sensitive detection of physical quantities such as magnetic and electric fields and temperature. Exploiting collective behaviour of non-interacting spins holds the promise of pushing the detection limit to even lower levels, while to date, those levels are scarcely reached due to the broadened linewidth and inefficient readout of solid-state spin ensembles. Here, we experimentally demonstrate that such drawbacks can be overcome by newly reborn maser technology at room temperature in the solid state. Owing to maser action, we observe a 4-fold reduction in the inhomogeneously broadened linewidth of a molecular spin ensemble, which is narrower than the same measured from single spins at cryogenic temperatures. The maser-based readout applied to magnetometry showcases a signal-to-noise ratio (SNR) of 30 dB for single shots. This technique would be a significant addition to the toolbox for boosting the sensitivity of solid-state ensemble spin sensors.
Quantum Physics,Applied Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **How to overcome the limitations of solid - state spin sensors in terms of sensitivity improvement by using room - temperature solid - state maser technology, especially the detection limit problems caused by inhomogeneous broadening and inefficient read - out**. ### Specific problem decomposition: 1. **Inhomogeneous broadening problem**: In solid - state spin - ensemble sensors, as the spin density increases, the complexity and variability of the local environment also increase, resulting in a broader resonance linewidth. This makes it difficult for sensors based on slope detection to sense slowly changing physical quantities (such as near - DC magnetic fields or biological temperature changes). 2. **Inefficient read - out problem**: The currently most commonly used optical read - out technique relies on detecting spin - state - related photoluminescence (PL), but this method is limited by non - negligible photon noise, resulting in low read - out fidelity. Even for spin ensembles, although the collected PL signal is amplified, due to the influence of background fluorescence, the measurement contrast is reduced, further limiting the sensitivity. ### The method proposed in the paper: The paper introduces the **room - temperature solid - state maser technology** and uses the threshold behavior and microwave amplification in the maser effect to solve the above two problems simultaneously: - **Linewidth narrowing**: Through the maser effect, the inhomogeneous broadening of molecular spin ensembles can be significantly reduced, and a 4 - fold linewidth narrowing has been observed in the experiment. - **Signal enhancement**: The maser - enhanced read - out technique can greatly improve the signal - to - noise ratio (SNR) of a single measurement. For example, an SNR of 30 dB has been achieved in magnetic measurements. ### Summary: The core objective of the paper is to verify the concept of maser - enhanced quantum sensing and demonstrate its potential in improving the sensitivity of solid - state spin - ensemble sensors. This method not only solves the main bottlenecks of current solid - state spin sensors but also provides a new approach for developing more sensitive quantum sensors in the future, especially for applications in magnetic fields, electric fields, and dark matter detection.