High-resolution EEG source localization in personalized segmentation-free head model with multi-dipole fitting
Akimasa Hirata,Masamune Niitsu,Chun Ren Phang,Sachiko Kodera,Tetsuo Kida,Essam A Rashed,Masaki Fukunaga,Norihiro Sadato,Toshiaki Wasaka
DOI: https://doi.org/10.1088/1361-6560/ad25c3
IF: 3.5
2024-02-03
Physics in Medicine and Biology
Abstract:Objective. Electroencephalograms (EEGs) are often used to monitor brain activity. Several source localization methods have been proposed to estimate the location of brain activity corresponding to EEG readings. However, only a few studies evaluated source localization accuracy from measured EEG using personalized head models in a millimeter resolution. In this study, based on a volume conductor analysis of a high-resolution personalized human head model constructed from magnetic resonance images, a finite difference method was used to solve the forward problem and to reconstruct the field distribution. Approach. We used a personalized segmentation-free head model developed using machine learning techniques, in which the abrupt change of electrical conductivity occurred at the tissue interface is suppressed. Using this model, a smooth field distribution was obtained to address the forward problem. Next, multi-dipole fitting was conducted using EEG measurements for each subject (N = 10 male subjects, age: 22.5 ± 0.5), and the source location and electric field distribution were estimated. Main results. For measured somatosensory evoked potential for electrostimulation to the wrist, a multi-dipole model with lead field matrix computed with the volume conductor model was superior than a single dipole model when using personalized segmentation-free models (6/10). The correlation coefficient between measured and estimated scalp potentials was 0.89 for segmentation-free head models and 0.71 for conventional segmented models. The proposed method is straightforward model development and comparable localization difference of the maximum electric field from the target wrist reported using fMR (i.e., 16.4 ± 5.2 mm) in previous study. For comparison, DUNEuro based on sLORETA was (EEG: 17.0±4.0 mm). Significance. For measured EEG signals, our procedures using personalized head models demonstrated that effective localization of the somatosensory cortex, which is located in a non-shallower cortex region. This method may be potentially applied for imaging brain activity located in other non-shallow regions.
engineering, biomedical,radiology, nuclear medicine & medical imaging