Transfemoral‐only transcatheter aortic valve replacement: A single center experience of 400 consecutive patients

Federico Moccetti,Mathias Wolfrum,Matthias Bossard,Adrian Attinger‐Toller,Lucca Loretz,Florim Cuculi,Stefan Toggweiler
DOI: https://doi.org/10.1002/ccd.31077
IF: 2.3
2024-05-14
Catheterization and Cardiovascular Interventions
Abstract:Background In transcatheter aortic valve replacement (TAVR), transfemoral (TF) access offers several advantages over alternative access routes. Advances in sheaths and valve delivery technology have catalyzed the feasibility of TF‐TAVR, even in challenging anatomies. Aims Report procedural characteristics and outcomes of a TAVR program aiming for a 100% TF access rate. Methods Consecutive patients undergoing TAVR were enrolled in a prospective registry. Equipment used to facilitate TF‐access in challenging anatomies included low‐profile sheaths, dilatators, peripheral balloons, covered and uncovered self‐expanding and balloon‐expandable stents, and intravascular lithotripsy (IVL). Results A total of 400 patients with a mean age of 81 ± 6 years (42% female) were analyzed. Minimal iliofemoral artery diameter (MLD) of the main access side was <5 mm in 42 (10.5%), extreme tortuosity was present in 65 (16.3%), and severe calcification in 59 (14.8%). TF‐access was successful in 399 (99.8%) patients. A transaxillary access was used in one patient. In multivariable analysis, an MLD 99% of patients. However, rates of vascular and bleeding complications in patients with narrow iliofemoral arteries (MLD
cardiac & cardiovascular systems
What problem does this paper attempt to address?