Investigation on fine water mist battery thermal management system for thermal runaway control
Tong Liu,Jian Hu,Qi Tang,Xiaolong Zhu,Yangpeng Liu,Xishi Wang
DOI: https://doi.org/10.1016/j.applthermaleng.2022.118474
IF: 6.4
2022-07-01
Applied Thermal Engineering
Abstract:The mist cooling system presents the ability of thermal management and hazard control for li-ion batteries, which can be developed into a compatible system with appropriate optimization. However, to have deeper insight into the mist cooling system, its effectiveness on thermal runaway (TR) hazard control still needs further experimental investigation. In this study, experiments have been conducted with the fine water mist (FWM) under TR conditions, and the influence of air velocity on hazard control has been discussed. Compared with air cooling, the FWM cooling system presents the maximum improvement of 46 %. The local evaporation cooling of the FWM droplets has been significantly weakened once the net droplets content reaches below 6.2 gm−3. Based on the heat generation during cooling, the comprehensive total temperature increase has been proposed to characterize the hazard control effect. Accordingly, the TR cooling control has been divided into three levels, and a conservative temperature of 240 °C is identified to guide the hazard control. This work confirms the TR control capacity of the FWM cooling system, and the influence of air velocity and droplets content on cooling capacity has been demonstrated, indicating the possibility of practical utilization in real cases.
energy & fuels,engineering, mechanical,thermodynamics,mechanics