High-Uniformity Calculation Method of Four-Coil Configuration in Large-Caliber Magnetic Field Immunity Testing System

Xi Deng,Ya Huang,Chenguang Wan,Li Jiang,Ge Gao,Zhengyi Huang,Jie Zhang
DOI: https://doi.org/10.1109/TPS.2022.3173043
2022-01-12
Abstract:Power electronic equipment regulated by the International Thermonuclear Experimental Reactor (ITER) organization must pass the relevant steady-state magnetic field immunity test. The main body of magnetic field immunity test is magnetic field generator coil. Through mathematical derivation in this paper, the magnetic field calculation formulas of four-coil configuration under ideal and actual models are obtained. The traditional method of magnetic field performance calculation is compared with the general formula method under the ideal model. A global parameter optimization method based on Lagrange Multiplier by KKT conditions is proposed to obtain the coil parameters of high-uniformity magnetic field. The magnetic field distribution in the uniform zone is revealed by the finite element method. The model analysis is proved to be correct and effective by experimental results. The research of this paper provides a practical scheme for the coil design with high magnetic field and high-quality uniformity.
Instrumentation and Detectors
What problem does this paper attempt to address?