Sensor characterization for the ULTRASAT space telescope

Benjamin Bastian-Querner,Nirmal Kaipachery,Daniel Küsters,Julian Schliwinski,Shay Alfassi,Arooj Asif,Merlin F. Barschke,Sagi Ben-Ami,David Berge,Adi Birman,Rolf Bühler,Nicola De Simone,Amos Fenigstein,Avishay Gal-Yam,Gianluca Giavitto,Juan M. Haces Crespo,Dmitri Ivanov,Omer Katz,Marek Kowalski,Shrinivasrao R. Kulkarni,Ofer Lapid,Tuvia Liran,Ehud Netzer,Eran O. Ofek,Sebastian Philipp,Heike Prokoph,Shirly Regev,Yossi Shvartzvald,Mikhail Vasilev,Dmitry Veinger,Jason J. Watson,Eli Waxman,Steven Worm,Francesco Zappon
DOI: https://doi.org/10.1117/12.2593897
2021-08-05
Abstract:The Ultraviolet Transient Astronomical Satellite is a scientific space mission carrying an astronomical telescope. The mission is led by the Weizmann Institute of Science in Israel and the Israel Space Agency, while the camera in the focal plane is designed and built by Deutsches Elektronen Synchrotron in Germany. Two key science goals of the mission are the detection of counterparts to gravitational wave sources and supernovae. The launch to geostationary orbit is planned for 2024. The telescope with a field-of-view of $\approx200$deg$^2$, is optimized to work in the near-ultraviolet band between $220$ and $280$nm. The focal plane array is composed of four $22.4$-megapixel, backside-illuminated CMOS sensors with a total active area of 90x90mm$^2$. Prior to sensor production, smaller test sensors have been tested to support critical design decisions for the final flight sensor. These test sensors share the design of epitaxial layer and anti-reflective coatings (ARC) with the flight sensors. Here, we present a characterization of these test sensors. Dark current and read noise are characterized as a function of the device temperature. A temperature-independent noise level is attributed to on-die infrared emission and the read-out electronics` self-heating. We utilize a high-precision photometric calibration setup to obtain the test sensors` quantum efficiency (QE) relative to PTB/NIST-calibrated transfer standards ($220$-$1100$nm), the quantum yield for $\lambda < 300$nm, the non-linearity of the system, and the conversion gain. The uncertainties are discussed in the context of the newest results on the setup`s performance parameters. From three ARC options, Tstd, T1 and T2, the latter optimizes out-of-band rejection and peaks in the mid of the ULTRASAT operational waveband (max. QE $\approx80\%$ at $245\mathrm{nm}$). We recommend ARC option T2 for the final ULTRASAT UV sensor.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?