Superfluid Liquid Helium Control for the Primordial Inflation Polarization Explorer Balloon Payload

A. Kogut,T. Essinger-Hileman,D. Fixsen,L. Lowe,P.Mirel,E. Switzer,E. Wollack
DOI: https://doi.org/10.1063/5.0048800
2021-05-19
Abstract:The Primordial Inflation Polarization Explorer (PIPER) is a stratospheric balloon payload to measure polarization of the cosmic microwave background. Twin telescopes mounted within an open-aperture bucket dewar couple the sky to bolometric detector arrays. We reduce detector loading and photon noise by cooling the entire optical chain to 1.7 K or colder. A set of fountain-effect pumps sprays superfluid liquid helium onto each optical surface, producing helium flows of 50--100 cm^3 / s at heights up to 200 cm above the liquid level. We describe the fountain-effect pumps and the cryogenic performance of the PIPER payload during two flights in 2017 and 2019.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?