WHO International Standard for SARS-CoV-2 Antibodies to Determine Markers of Protection
Feng Zhu,Thomas Althaus,Chee Wah Tan,Alizee Costantini,Wan Ni Chia,Nguyen Van Vinh Chau,Le Van Tan,Giada Mattiuzzo,Nicola J. Rose,Eric Voiglio,Lin-Fa Wang
DOI: https://doi.org/10.1016/s2666-5247(21)00307-4
IF: 86.208
2021-01-01
The Lancet Microbe
Abstract:Several studies have shown that neutralising antibody level is a good biomarker for the correlate of protection against SARS-CoV-2 infection.1Bergwerk M Gonen T Lustig Y et al.COVID-19 breakthrough infections in vaccinated health care workers.N Engl J Med. 2021; 385: 1474-1484Crossref PubMed Scopus (836) Google Scholar, 2Khoury DS Cromer D Reynaldi A et al.Neutralizing antibody levels are highly predictive of immune protection from symptomatic SARS-CoV-2 infection.Nat Med. 2021; 27: 1205-1211Crossref PubMed Scopus (2073) Google Scholar, 3Feng S Phillips DJ White T et al.Correlates of protection against symptomatic and asymptomatic SARS-CoV-2 infection.medRxiv. 2021; (published online June 24.) (preprint).https://doi.org/10.1101/2021.06.21.21258528Google Scholar However, results from these studies are presented using assays that have not been calibrated using a common reference standard, making it difficult to define the exact level of neutralising antibodies required for protection and to compare with current and future studies. The most recent study4Gilbert PB Montefiori DC McDermott A et al.Immune correlates analysis of the mRNA-1273 COVID-19 vaccine efficacy trial.medRxiv. 2021; (published online Aug 15.) (preprint).https://doi.org/10.1101/2021.08.09.21261290Google Scholar is the only one we have identified that reports the neutralising antibody level using WHO international units by calibrating their neutralisation assays against the WHO international standard for SARS-CoV-2 immunoglobulin; the international standard was established by the WHO Expert Committee on Biological Standardization as a primary calibrant to harmonise the measurement of anti-SARS-CoV-2 antibodies and was made available in December, 2020 from the WHO Collaborative centre, the National Institute for Biological Standards and Control (NIBSC), UK.5Kristiansen PA Page M Bernasconi V et al.WHO International Standard for anti-SARS-CoV-2 immunoglobulin.Lancet. 2021; 397: 1347-1348Summary Full Text Full Text PDF PubMed Scopus (205) Google Scholar As highlighted by the study on breakthrough infections from BNT162b2 vaccinees in Israel,1Bergwerk M Gonen T Lustig Y et al.COVID-19 breakthrough infections in vaccinated health care workers.N Engl J Med. 2021; 385: 1474-1484Crossref PubMed Scopus (836) Google Scholar neutralising antibody titres are typically not readily available in most studies due to the cost and time consuming nature of any cell-based virus neutralisation test, whether using the live virus or a pseudotyped virus. Most research groups are thus relying on determining levels of binding anti-spike, subunit 1, or anti-receptor binding domain antibodies as immune correlates. However, the same study showed that the correlation between neutralising antibody levels and breakthrough infections was stronger than that for IgG binding antibodies.1Bergwerk M Gonen T Lustig Y et al.COVID-19 breakthrough infections in vaccinated health care workers.N Engl J Med. 2021; 385: 1474-1484Crossref PubMed Scopus (836) Google Scholar Many surrogate neutralisation assays are entering the market.6Kohmer N Rühl C Ciesek S Rabenau HF Utility of different surrogate enzyme-linked immunosorbent assays (sELISAs) for detection of SARS-CoV-2 neutralizing antibodies.J Clin Med. 2021; 10: 2128Crossref PubMed Scopus (36) Google Scholar These assays offer a rapid and user-friendly way to determine neutralising antibody titres; usually they are based on the competitive inhibition of the interaction between the SARS-CoV-2 spike protein and the angiotensin-converting enzyme 2 cell surface receptor. To date, only one assay detecting neutralising antibody has received US Food and Drug Administration authorisation: a surrogate virus neutralisation test7Tan CW Chia WN Qin X et al.A SARS-CoV-2 surrogate virus neutralization test based on antibody-mediated blockage of ACE2-spike protein-protein interaction.Nat Biotechnol. 2020; 38: 1073-1078Crossref PubMed Scopus (722) Google Scholar that was commercialised under the trade name cPass (GenScript, Singapore). Furthermore, to increase comparability of the neutralising antibody levels across different studies, cPass has been calibrated against the WHO International Standard (NIBSC code 20/136). Using data representing 21 biological replicates from three international groups (appendix), we obtained a highly reproducible calibration of cPass reading (% inhibition) to IU/mL of the WHO International Standard with a pseudo R2Khoury DS Cromer D Reynaldi A et al.Neutralizing antibody levels are highly predictive of immune protection from symptomatic SARS-CoV-2 infection.Nat Med. 2021; 27: 1205-1211Crossref PubMed Scopus (2073) Google Scholar (1 – deviance/null.deviance) at 0·978. We have developed a convenient Excel-based conversion tool that is freely available online. Bergwerk and colleagues' study on neutralising antibodies as correlates of protection against infection by the alpha variant showed that the geometric mean titre of neutralising antibodies, determined using pseudotyped virus-based virus neutralisation test, from the infected group of 22 cases was about 2·76-fold (peri-infection level) to 6·76-fold (peak level) lower than that of the matched control group of 104 individuals.1Bergwerk M Gonen T Lustig Y et al.COVID-19 breakthrough infections in vaccinated health care workers.N Engl J Med. 2021; 385: 1474-1484Crossref PubMed Scopus (836) Google Scholar Using the mean pseudotyped virus neutralisation test titre to IU/mL conversion from the WHO report, we can speculate that the peri-infection neutralising antibody levels are at 99 and 250 IU/mL and the peak neutralising antibody levels at 82 IU/mL and 448 IU/mL for the infected and control groups, respectively. The observation that, for the infected group, the peri-infection neutralising antibody level was slightly higher than the peak neutralising antibody level would suggest some boosting effect for some infected individuals, given that the sampling time in relation to infection was not uniform. The authors thus concluded that the peak neutralising antibody level is a better predictor of correlate for protection than the peri-infection neutralising antibody level is.1Bergwerk M Gonen T Lustig Y et al.COVID-19 breakthrough infections in vaccinated health care workers.N Engl J Med. 2021; 385: 1474-1484Crossref PubMed Scopus (836) Google Scholar From the study on delta variant breakthrough infection in Vietnam, neutralising antibodies were measured directly with cPass for fully vaccinated health-care workers who received the AstraZeneca vaccine.8Chau NVV Ngoc NM Nguyet LA et al.An observational study of breakthrough SARS-CoV-2 delta variant infections among vaccinated healthcare workers in Vietnam.EClinicalMedicine. 2021; 41: 101143Summary Full Text Full Text PDF PubMed Scopus (57) Google Scholar There are two cohorts presented in this study. Neutralising antibody levels for the first cohort were available both at 8 weeks after the first dose and during the peri-infection period. By conversion of cPass reading (% inhibition) to IU/mL as stated above, we calculated that the peri-infection neutralising antibody levels were 100 IU/mL (geometric mean [GM] 94) and 738 IU/mL (GM 530) for the infected (n=10) and control (n=30) groups, respectively. The neutralising antibody levels at 8 weeks after the first dose were 157 IU/mL (GM 167) and 757 IU/mL (GM 623), respectively. For the second larger cohort, only peri-infection neutralising antibody levels were available, which were 151 IU/mL (GM 170) and 328 IU/mL (GM 300) IU/mL for the infected (n=59) and control (n=59) groups, respectively. Using the cPass data from a longitudinal neutralising antibody follow-up study of a COVID-19 cohort (n=164) in Singapore,9Chia WN Zhu F Ong SWX et al.Dynamics of SARS-CoV-2 neutralising antibody responses and duration of immunity: a longitudinal study.Lancet Microbe. 2021; 2: e240-e249Summary Full Text Full Text PDF PubMed Scopus (235) Google Scholar we observed that at 6 months post-infection (or the last time point available), the mean neutralising antibody level was 332 IU/mL (GM 53, median 44), ranging from 0 to 3000 IU/mL (maximum modelling value for IU at the cPass value of 97·57). Using the threshold of 82 IU/mL from the study in Israel, 93 individuals (57%) had a peak neutralising antibody level at this threshold or below, indicating that they might be susceptible for reinfection by the alpha variant. Similarly, using the threshold of 170 IU/mL (GM) from the study in Vietnam, 112 individuals (68%) had neutralising antibody levels below the threshold and, hence, might be potentially susceptible for reinfection by the delta variant. It should be emphasised that, due to the small number of samples in the different studies, the threshold IU/mL defined in this analysis needs further validation with bigger cohort studies. However, the observation that the breakthrough infection of the delta variant could occur at a higher threshold than that of the alpha variant is consistent with published findings.10Cromer D Steain M Reynaldi A et al.SARS-CoV-2 variants: levels of neutralisation required for protective immunity.medRxiv. 2021; (published online Aug 13.) (preprint).https://doi.org/10.1101/2021.08.11.21261876PubMed Google Scholar With the global population being vaccinated at an increased pace and many individuals being shown to be susceptible to breakthrough infections, there is an urgent need to develop a harmonised approach for risk assessment among different populations using different vaccines. Surrogate neutralisation assays calibrated to the WHO international standard, such as cPass, represent a good first step towards such an international harmonisation goal. More so than ever, with the delta variant spreading rapidly across the globe, a harmonised approach for the assessment of risk and correlate of protection is highly desirable. CWT, WNC, and L-FW are co-inventors of the surrogate virus neutralisation technology that has been commercialised under the trade name cPass by GenScript Biotech. GM provided independent expertise on the calibration of assays using the WHO IS. There is no endorsement of any individual assay, diagnostic product or vaccine by the NIBSC authors (GM and NJR). We thank Yun Sun, Wan Su, Lam Anh Nguyet, Tran Tan Thanh, Shuting Xu, and Yanfeng Li for technical assistance and coordination of different study groups. Download .xlsx (.14 MB) Help with xlsx files Supplementary appendix