Time-resolved cryo-EM (TRCEM) sample preparation using a PDMS-based microfluidic chip assembly

Xiangsong Feng,Joachim Frank
DOI: https://doi.org/10.1101/2024.12.08.627437
2024-12-09
Abstract:Time-resolved cryo-EM (TRCEM) makes it possible to provide structural and kinetic information on a reaction of biomolecules before the equilibrium is reached. Several TRCEM methods have been developed in the past to obtain key insights into the mechanism of action of molecules and molecular machines on the time scale of tens to hundreds of milliseconds, which is unattainable by the normal blotting method. Here we present our TRCEM setup utilizing a polydimethylsiloxane (PDMS)-based microfluidics chip assembly, comprising three components: a PDMS-based, internally SiO2-coated micromixer, a glass-capillary microreactor, and a PDMS-based microsprayer for depositing the reaction product onto the EM grid. As we have demonstrated in recent experiments, this setup is capable of addressing problems of severe sample adsorption and ineffective mixing of fluids, and leads to highly reproducible results in applications to the study of translation. As an example, we used our TRCEM sample preparation method to investigate the molecular mechanism of ribosome recycling mediated by High frequency of lysogenization X (HflX), which demonstrated the efficacy of the TRCEM device and its capability to yield biologically significant, reproducible information. This protocol has promise to provide structural and kinetic information on pre-equilibrium intermediates in the 10 -1000 ms time range in applications to many other biological systems.
Biophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: how to obtain the structural and kinetic information of biomolecular reactions through time - resolved cryo - electron microscopy (TRCEM) technology within the time range of 10 to 1000 milliseconds. Specifically, the author aims to overcome two main problems in the existing TRCEM methods: 1. **Severe sample adsorption**: Some materials (such as PDMS) are highly hydrophobic and are likely to cause the adsorption of biological samples, thus affecting the experimental results. 2. **Poor mixing effect**: Under laminar flow conditions, the performance of micro - mixers is limited, resulting in non - uniform liquid mixing, which in turn affects the controllability and repeatability of the reaction. To solve these problems, the author has developed a microfluidic chip device based on polydimethylsiloxane (PDMS), which includes three key components: - **PDMS - based, internally SiO₂ - coated micro - mixer**: Adopting a three - dimensional self - crossing channel design, it can efficiently mix solutions and ensure the uniform initiation of the reaction. - **Glass capillary micro - reactor**: Used to precisely control the liquid flow rate and define the reaction time. - **PDMS - based micro - injector**: Used to evenly spray the reaction products onto the EM grid to prepare high - quality cryo - electron microscopy samples. Through these improvements, the author hopes to obtain higher - quality time - resolved cryo - electron microscopy samples within the time range of 10 to 1000 milliseconds, thereby revealing the intermediate states of biomolecular reactions and their kinetic processes. For example, they used this method to study the ribosome recycling mechanism mediated by high - frequency lysogen X (HflX), demonstrating the effectiveness and repeatability of this TRCEM device. In summary, the main objective of this paper is to improve the understanding of the dynamic processes of biomolecular reactions, especially the structural and kinetic information on the millisecond time scale, by optimizing the TRCEM sample preparation method.