Detection of Unlabeled Micro- and Nanoplastics in Unstained Tissue with Optical Photothermal Infrared Spectroscopy

Kristina Duswald,Verena Pichler,Verena Kopatz,Tanja Limberger,Verena Karl,David Wimberger,Robert Zimmerleiter,Wolfgang Wadsak,Mike Hettich,Lukas Kenner,Markus Brandstetter
DOI: https://doi.org/10.1101/2024.11.11.622943
2024-11-12
Abstract:In this study, we investigate the efficacy of Optical Photothermal Infrared (O-PTIR) spectroscopy, also known as mid-infrared photothermal (MIP) microscopy, for the detection of micro- and nano plastics (MNPs) down to diameters of 250 nm in mammalian tissues. Experiments with both in vitro 3D cell cultures derived from HTC116 colorectal cancer cell line and in vivo mouse tissue models were conducted to evaluate the spatial resolution limits and quality of spectra that formed the basis for label-free and non-destructive identification of MNPs. Our findings demonstrate the superior resolution of O-PTIR in imaging individual particles of 250 nm in mouse kidney tissues, surpassing the capabilities of traditional FTIR spec-troscopy, which was applied as a reference technique. Furthermore, we introduce a semi-automated image analysis that incorporates machine learning algorithms to accelerate the detection process, thus improving throughput and minimizing the potential for human error. The results confirm that O-PTIR produces high-quality, artefact-free spectral images in a contact-less manner and significantly outperforms FTIR in terms of spatial resolution and signal-to-noise ratio in complex biological matrices.
Biophysics
What problem does this paper attempt to address?
### What problems does this paper attempt to solve? This paper aims to address the challenges in the detection of microplastics and nanoplastics (MNPs) in biological tissues. Specifically, the research focuses on: 1. **Developing high - resolution, non - invasive detection methods**: Traditional Fourier - transform infrared spectroscopy (FTIR) techniques, due to the limitation of the optical diffraction limit, can usually only detect particles with a diameter greater than 10 micrometers and are easily affected by artifacts in reflectance measurements. Therefore, this study introduced **Optical - Photothermal Infrared Spectroscopy (O - PTIR)** technology to achieve high - resolution, label - free, non - destructive detection of microplastics and nanoplastics with a diameter as low as 250 nanometers. 2. **Improving detection efficiency and accuracy**: By combining machine - learning algorithms, the study developed a semi - automatic image analysis method to accelerate the detection process and reduce human error. This not only increases the detection speed but also ensures the consistency and reliability of the results. 3. **Preserving spatial information**: Many existing detection methods require the separation of microplastics from biological tissues, which is not only time - consuming but may also lead to changes in chemical composition or the loss of specific polymer types. More importantly, this separation process will lose the precise location information of microplastics in the tissue. The O - PTIR technology can directly detect the distribution of microplastics in the tissue without separating them, thus preserving important spatial information. 4. **Evaluating the health impacts of microplastics**: The widespread presence of microplastics worldwide and their potential threats to human health have become an increasingly serious problem. Studies have shown that frequent exposure to high - concentrations of microplastics may increase the risk of diseases such as colorectal cancer. Therefore, developing reliable detection methods is crucial for evaluating the accumulation of microplastics in human tissues and their potential health impacts. ### Key Conclusions - The O - PTIR technology performs excellently in detecting microplastics and nanoplastics, especially significantly outperforming traditional FTIR technology in terms of spatial resolution and signal - to - noise ratio in complex biological matrices. - The application of the semi - automatic image analysis method improves detection efficiency and reduces human error. - The O - PTIR technology can preserve the precise location information of microplastics in the tissue without destroying the sample, providing a basis for detailed analysis of the interaction between microplastics and tissues. Through these improvements, the study provides a new, efficient and reliable method for the detection and analysis of microplastics in environmental and biological systems.