Flexible 3D kirigami probes for in vitro and in vivo neural applications

Marie Jung,Jamal Abu Shihada,Simon Decke,Lina Koschinski,Peter Severin Graff,Sebastian Maruri Pazmino,Anke Hoellig,Henner Koch,Simon Musall,Andreas Offenhaeusser,Viviana Rincon Montes
DOI: https://doi.org/10.1101/2024.11.05.622167
2024-11-05
Abstract:Three-dimensional (3D) microelectrode arrays (MEAs) are gaining popularity as brain-machine interfaces and platforms for studying electrophysiological activity. Interactions with neural tissue depend on the electrochemical, mechanical, and spatial features of the recording platform. While planar or protruding two-dimensional MEAs are limited in their ability to capture neural activity across layers, existing 3D platforms still require advancements in manufacturing scalability, spatial resolution, and tissue integration. In this work, we present a customizable, scalable, and straightforward approach to fabricate flexible 3D kirigami MEAs containing both surface and penetrating electrodes, designed to interact with the 3D space of neural tissue. These novel probes feature up to 512 electrodes distributed across 128 shanks in a single flexible device, with shank heights reaching up to 1 mm. We successfully deployed our 3D kirigami MEAs in several neural applications, both in vitro and in vivo, and identified spatially dependent electrophysiological activity patterns. Flexible 3D kirigami MEAs are therefore a powerful tool for large-scale electrical sampling of complex neural tissues while improving tissue integration and offering enhanced capabilities for analyzing neural disorders and disease models where high spatial resolution is required.
Neuroscience
What problem does this paper attempt to address?
The problems that this paper attempts to solve are the limitations of existing three - dimensional (3D) microelectrode arrays (MEAs) in terms of manufacturing scalability, spatial resolution, and tissue integration. Specifically: 1. **Manufacturing Scalability**: Existing 3D MEA manufacturing techniques usually face problems such as complex manual operations, time - consuming processes, and difficulty in achieving large - scale parallel production. 2. **Spatial Resolution**: Existing 3D MEAs have limited sampling capabilities when capturing neural activities, especially in multi - layer neural tissues, and cannot provide high - resolution spatial coverage. 3. **Tissue Integration**: Due to the mismatch between the mechanical properties of existing 3D MEAs and soft tissues, they are prone to strong foreign - body reactions (FBRs), which affect their long - term stability and biocompatibility. To solve these problems, researchers have developed a new, customizable, and scalable method for manufacturing flexible 3D kirigami MEAs. These new - type probes contain surface and penetrating electrodes and are designed to interact with the three - dimensional space of neural tissues. These probes have the following characteristics: - **High Resolution**: Each device contains up to 512 electrodes, distributed over 128 probes, with a probe height of up to 1 millimeter. - **Flexibility and Biocompatibility**: Flexible materials (such as parylene - C) are used to improve compatibility with soft tissues and reduce foreign - body reactions. - **Scalability and Customization**: Through the matched - die molding process, a fast and repeatable manufacturing process is achieved, supporting multiple designs to meet different neural application requirements. Overall, this research aims to provide a powerful tool for large - scale electrical sampling of complex neural tissues, while improving tissue integration and providing enhanced capabilities for analyzing neural disease models.