Derivation and validation of a prediction rule for sedative-associated delirium during acute respiratory failure requiring mechanical ventilation

Niall T Prendergast,Chukwudi A Onyemekwu,Kelly M Potter,Christopher A Franz,Georgios D Kitsios,Bryan J McVerry,Pratik P Pandharipande,E Wes Ely,Timothy D Girard
DOI: https://doi.org/10.1101/2024.09.30.24314628
2024-10-01
Abstract:Abstract Background: Delirium during acute respiratory failure is common and morbid. Pharmacologic sedation is a major risk factor for delirium, but some sedation is often necessary for the provision of safe care of mechanically ventilated patients. A simple, transparent model that predicts sedative-associated delirium in mechanically ventilated ICU patients could be used to guide decisions about personalized sedation. Research Question: Can the risk of sedative-associated delirium be estimated in mechanically-ventilated ICU patients? Study Design and Methods: Using the subset of patients in a previously-published ICU cohort who received mechanical ventilation, we performed backward stepwise logistic regression to derive a model predictive of sedative-associated delirium. We validated this model internally using hundredfold bootstrapping. We then validated this model externally in a separate prospective cohort of mechanically ventilated ICU patients. Results: 836 patients comprised the derivation cohort. Backwards stepwise regression produced a model with age, BMI, sepsis, SOFA, malignancy, COPD, stroke, sex, and doses of sedatives (opioids, propofol, and/or benzodiazepines) as predictors of sedative-associated delirium. The model had very good discriminative power, with an area under the receiver-operator curve (AUROC) of 0.83. Internal validation via bootstrapping showed preserved discriminatory function with an AUROC of 0.81 and graphical evidence of good calibration. External validation in a separate set of 340 patients showed good discrimination, with AUROC of 0.70. Interpretation: Sedative-associated delirium during acute respiratory failure requiring mechanical ventilation can be predicted using a simple, transparent model, which can now be validated in a prospective study.
Intensive Care and Critical Care Medicine
What problem does this paper attempt to address?
The main problem this paper attempts to address is the development and validation of a predictive rule for sedative-associated delirium during mechanical ventilation in acute respiratory failure. Specifically, the researchers aim to construct a simple and transparent model to estimate the risk of sedative-associated delirium in mechanically ventilated ICU patients, thereby guiding clinicians in balancing risks and benefits when deciding on personalized sedation strategies, especially in the early stages post-intubation. ### Research Background - **Importance of the Problem**: Delirium is very common among patients requiring mechanical ventilation for acute respiratory failure and is associated with higher ICU and hospital mortality rates as well as long-term cognitive impairment. - **Impact of Sedative Drugs**: Although sedative drugs are one of the main risk factors for delirium, some level of sedation is often necessary in the care of mechanically ventilated patients. - **Limitations of Existing Tools**: There is currently a lack of evidence-based tools to guide sedation practices. Existing sedation scores are primarily used to assess the depth of sedation rather than to predict the risk of delirium. ### Research Objectives - **Develop a Predictive Model**: Develop a model to predict sedative-associated delirium by analyzing existing ICU patient data. - **Validate the Model's Effectiveness**: Ensure the model's accuracy and reliability through internal and external validation. ### Methods - **Data Sources**: Use data from mechanically ventilated patients in the BRAIN-ICU and MIND-ICU studies for model development and internal validation, followed by external validation in an independent cohort from the ALIR study. - **Statistical Methods**: Employ backward stepwise logistic regression to select predictive variables and use hundredfold bootstrapping for internal validation. External validation is performed by calculating the area under the receiver operating characteristic curve (AUROC). ### Results - **Model Performance**: The final model includes predictive variables such as age, BMI, sepsis, SOFA score, malignancy, COPD, history of stroke, gender, and doses of sedative drugs (opioids, propofol, and/or benzodiazepines). The model's internal validation AUROC is 0.81, and the external validation AUROC is 0.70, indicating good discrimination and calibration. ### Conclusion - **Practicality of the Model**: The model can accurately predict the risk of sedative-associated delirium in mechanically ventilated ICU patients, aiding clinicians in balancing risks and benefits when formulating personalized sedation plans. - **Future Directions**: Future research should further optimize the model and validate its impact on patient outcomes in clinical trials. Through this study, the authors hope to provide a practical tool for clinical decision-making to reduce the incidence of sedative-associated delirium and improve the quality of care for mechanically ventilated patients.