Reclaiming Hand Functions after Complete Spinal Cord Injury with Epidural Brain-Computer Interface

Dingkun Liu,Yongzhi Shan,Penghu Wei,Wenzheng Li,Honglai Xu,Fangshuo Liang,Tao Liu,Guoguang Zhao,Bo Hong
DOI: https://doi.org/10.1101/2024.09.05.24313041
2024-11-02
Abstract:Background: Spinal cord injuries significantly impair patients' ability to perform daily activities independently. While cortically implanted brain-computer interfaces (BCIs) offer high communication bandwidth to assist and rehabilitate these patients, their invasiveness and long-term stability limits broader adoption. Methods: We developed a minimally invasive BCI with 8 chronic epidural electrodes above primary sensorimotor cortex to restore hand functions of tetraplegia patients. With wireless powering and neural data transmission, this system enables real-time BCI control of hand movements and hand function rehabilitation in home use. A complete spinal cord injury (SCI) patient with paralyzed hand functions was recruited in this study. Results: Over a 9-month period of home use, the patient achieved an average grasping detection F1-score of 0.91, and a 100% success rate in object transfer tests, with this minimally invasive BCI and a wearable exoskeleton hand. This system allowed the patient to perform eating, drinking and other daily tasks involving hand functions. Additionally, the patient showed substantial neurological recovery through consecutive BCI training, regaining the ability to hold objects without BCI. The patient exhibited a 5-point improvement in upper limb motor scores and a 27-point increase in the action research arm test (ARAT). A maximal increase of 12.2 μV was observed in the peak of somatosensory evoked potential, which points to a considerable recovery in impaired spinal cord connections. Conclusions: In a tetraplegia patient with complete spinal cord injury, an epidural minimally invasive BCI assisted the patient's hand grasping to perform daily tasks, and 9-month consecutive BCI use significantly improved the hand functions.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: How to help patients with complete spinal cord injury (SCI) restore hand function through a minimally - invasive brain - computer interface (BCI) technology, enabling them to independently complete daily activities. Specifically, the research team has developed a brain - computer interface system based on epidural electrodes, aiming to help quadriplegic patients restore hand - gripping function and evaluate the long - term use effect of this system in the home environment and its impact on neural rehabilitation. ### Background Spinal cord injury (SCI) significantly affects patients' daily living abilities. Especially when the injury occurs in the cervical spine area, it will lead to complete paralysis of the limbs and loss of hand motor function. Although implantable brain - computer interfaces (BCI) can provide high - bandwidth communication to help patients with rehabilitation training, their invasiveness and long - term stability limit their wider application. ### Research Objectives 1. **Develop a minimally - invasive brain - computer interface system**: Restore hand function through eight chronic epidural electrodes placed above the primary sensorimotor cortex of the brain. 2. **Verify the long - term stability and effectiveness of the system**: Ensure that the system can achieve real - time control and hand function rehabilitation in the home environment through wireless power supply and neural data transmission. 3. **Evaluate the neural rehabilitation effect**: Study the changes in patients' hand function and nerve recovery after using the system continuously for 9 months. ### Main Findings - During the 9 - month home use period, the patient's average grip detection F1 score reached 0.91, and the success rate of the object transfer test was 100%. - The patient was able to complete daily tasks such as eating and drinking with the help of this system. - Through continuous BCI training, the patient showed significant nerve recovery, including an increase of 5 points in the upper limb movement score and an increase of 27 points in the ARAT score. - The peak of the somatosensory - evoked potential (SEP) increased by 12.2 μV, indicating a significant improvement in the damaged spinal cord connection. ### Conclusion For patients with quadriplegia caused by complete spinal cord injury, this minimally - invasive brain - computer interface system can not only assist patients in hand - gripping to complete daily tasks, but also significantly improve hand function after 9 months of continuous use. This research shows that by combining top - down motor control signals and bottom - up sensory feedback signals, neural rehabilitation can be promoted without relying on external electrical stimulation. ### Formula Display The formulas involved in the article are mainly concentrated in signal processing and evaluation, for example: - **F1 score calculation**: \[ F1 = 2\times\frac{\text{Precision}\times\text{Recall}}{\text{Precision}+\text{Recall}} \] - **Event - related spectral perturbation (ERSP)**: \[ \text{ERSP}(t, f)=\frac{P(t, f)-P_{\text{baseline}}(f)}{P_{\text{baseline}}(f)} \] These formulas show the key indicators used for evaluation and analysis in the research.