Obtaining super-resolved images at the mesoscale through Super-Resolution Radial Fluctuations

Mollie Brown,Shannan Foylan,Liam M Rooney,Gwyn W Gould,Gail McConnell
DOI: https://doi.org/10.1101/2024.07.31.606008
2024-08-01
Abstract:Super-resolution microscopy overcomes the diffraction limit of light to achieve higher spatial resolutions than are typically available when using light microscopy techniques. However, these methods are usually restricted to imaging a very small field of view (FOV). Here, we have applied one of these super-resolution techniques, Super-Resolution Radial Fluctuations (SRRF) in conjunction with the Mesolens, which has the unusual combination of a low-magnification and high numerical aperture, to obtain super-resolved images over a FOV of 4.4 mm x 3.0 mm. We assessed the accuracy of these SRRF images through error maps calculated using a secondary analysis method, Super-resolution Quantitative Image Rating and Reporting of Error Locations (SQUIRREL). We demonstrate it is possible to achieve images with a resolution of 446.3 +/- 10.9 nm, providing a ~1.6-fold improvement in spatial resolution over a uniquely large field, with consistent structural agreement between raw data and SRRF processed images.
Biophysics
What problem does this paper attempt to address?
The paper attempts to address the issue of obtaining high-resolution images at the mesoscale using Super-Resolution Radial Fluctuations (SRRF) technology. Specifically: Current super-resolution imaging techniques, while enhancing the understanding of cellular structures, typically can only image very small Fields of View (FOV), which may not represent the behavior of the entire sample. Additionally, manually selecting Regions of Interest (ROI) can introduce bias. Although stitching and tiling methods can combine multiple small ROIs, they can create artifacts in the images, affecting data analysis. To address these issues, researchers used the Mesolens with low magnification and high Numerical Aperture (NA), combined with SRRF analysis, to obtain super-resolution images with a 4.4 mm × 3.0 mm FOV, minimizing errors. Using this method, researchers demonstrated that it is possible to achieve a spatial resolution of approximately 446.3 ± 10.9 nm while maintaining a large FOV, which is about 1.6 times better than traditional methods. Additionally, they verified the consistency between SRRF-processed images and the original images, proving that this method is suitable not only for filamentous structures but also for imaging non-filamentous cellular structures.