AI-based volumetric six-tissue body composition quantification from CT cardiac attenuation scans enhances mortality prediction: multicenter study

Jirong Yi,Anna M Michalowska,Aakash Shanbhag,Robert Miller,Jolien Geers,Wenhao Zhang,Aditya Killekar,Nipun Manral,Mark Lemley,Mikolaj Buchwald,Jacek Kwiecinski,Jianhang Zhou,Paul Kavanagh,Joanna Liang,Valerie Builoff,Terrence Ruddy,Andrew J. Einstein,Attila Feher,Edward J Miller,Albert Sinusas,Daniel Berman,Damini Dey,Piotr Slomka
DOI: https://doi.org/10.1101/2024.07.30.24311224
2024-08-01
Abstract:Background: Computed tomography attenuation correction (CTAC) scans are routinely obtained during cardiac perfusion imaging, but currently only utilized for attenuation correction and visual calcium estimation. We aimed to develop a novel artificial intelligence (AI)-based approach to obtain volumetric measurements of chest body composition from CTAC scans and evaluate these measures for all-cause mortality (ACM) risk stratification. Methods: We applied AI-based segmentation and image-processing techniques on CTAC scans from a large international image-based registry (four sites), to define chest rib cage and multiple tissues. Volumetric measures of bone, skeletal muscle (SM), subcutaneous, intramuscular (IMAT), visceral (VAT), and epicardial (EAT) adipose tissues were quantified between automatically-identified T5 and T11 vertebrae. The independent prognostic value of volumetric attenuation, and indexed volumes were evaluated for predicting ACM, adjusting for established risk factors and 18 other body compositions measures via Cox regression models and Kaplan-Meier curves. Findings: End-to-end processing time was <2 minutes/scan with no user interaction. Of 9918 patients studied, 5451(55%) were male. During median 2.5 years follow-up, 610 (6.2%) patients died. High VAT, EAT and IMAT attenuation were associated with increased ACM risk (adjusted hazard ratio (HR) [95% confidence interval] for VAT: 2.39 [1.92, 2.96], p<0.0001; EAT: 1.55 [1.26, 1.90], p<0.0001; IMAT: 1.30 [1.06, 1.60], p=0.0124). Patients with high bone attenuation were at lower risk of death as compared to subjects with lower bone attenuation (adjusted HR 0.77 [0.62, 0.95], p=0.0159). Likewise, high SM volume index was associated with a lower risk of death (adjusted HR 0.56 [0.44, 0.71], p<0.0001). Interpretations: CTAC scans obtained routinely during cardiac perfusion imaging contain important volumetric body composition biomarkers which can be automatically measured and offer important additional prognostic value.
Radiology and Imaging
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to use artificial intelligence (AI) technology to obtain volumetric measurements of thoracic body composition from cardiac CT attenuation correction (CTAC) scans and evaluate the value of these measurements for all - cause mortality (ACM) risk stratification. Specifically, the research team developed a new AI method that can automatically segment six key body tissues (bone, skeletal muscle, subcutaneous adipose tissue, intramuscular adipose tissue, visceral adipose tissue, and pericardial adipose tissue) from CTAC scans and evaluate the independent prognostic value of the volumetric measurements of these tissues in predicting all - cause mortality. ### Research Background CTAC scans are routinely obtained during cardiac perfusion imaging, but are currently only used for attenuation correction and visual calcium estimation. This study aims to develop an AI - based method to obtain volumetric measurements of thoracic body composition from CTAC scans and evaluate the application value of these measurements in all - cause mortality (ACM) risk stratification. ### Main Problems 1. **Develop AI Method**: Develop a fully - automatic AI method that can segment six key body tissues (bone, skeletal muscle, subcutaneous adipose tissue, intramuscular adipose tissue, visceral adipose tissue, and pericardial adipose tissue) from CTAC scans. 2. **Evaluate Prognostic Value**: Evaluate the independent prognostic value of the volumetric measurements of these body components in predicting all - cause mortality, adjusting for known risk factors and other body composition indicators. ### Methods - **Data Source**: Obtain CTAC scan data from large - scale imaging registry studies in four international centers. - **AI Segmentation**: Use existing CT segmentation models and image processing techniques to automatically identify multiple tissues between the T5 and T11 vertebral bodies. - **Statistical Analysis**: Evaluate the independent prognostic value of different body composition indicators in predicting all - cause mortality through Cox regression models and Kaplan - Meier curves. ### Results - **Processing Time**: The end - to - end processing time is less than 2 minutes per scan without user interaction. - **Sample Size**: A total of 9,918 patients were included, of which 5,451 were male. The median follow - up time was 2.5 years, during which 610 (6.2%) patients died. - **Prognostic Association**: - High densities of visceral adipose tissue (VAT), pericardial adipose tissue (EAT), and intramuscular adipose tissue (IMAT) were significantly associated with an increased all - cause mortality (adjusted hazard ratios HR were 2.39 [1.92, 2.96], p < 0.0001; 1.55 [1.26, 1.90], p < 0.0001; 1.30 [1.06, 1.60], p = 0.0124 respectively). - High bone density was associated with a lower risk of death (adjusted HR 0.77 [0.62, 0.95], p = 0.0159). - High skeletal muscle volume index was associated with a lower risk of death (adjusted HR 0.56 [0.44, 0.71], p < 0.0001). ### Explanation CTAC scans contain important body composition biomarkers, and these biomarkers can provide additional prognostic value through automatic measurement. These results indicate that CTAC scans can be used not only for attenuation correction but also for more comprehensive body composition analysis, thereby improving the clinical management and risk stratification of patients.