A low bias method for quantification of Oil Red O staining

Christian Feldhaus,Veysi Piskobulu
DOI: https://doi.org/10.1101/2024.06.18.599611
2024-06-19
Abstract:Oil Red O (ORO) is a well established dye for assessing the lipid content of nematodes. Previously reported methods for quantifying ORO staining rely on the difference in absorption in the red part of the spectrum wherORO appears transparent and parts of the spectrum where ORO absorbs light. However, several sources of bias and artifacts are usually not accounted for in previously described methods which makes them unsuitable to detect small differences in lipid content. Here we describe a method which relies on filter based acquisition and semi-automatic image processing including e.g. a correction for different background intensities to eliminate several sources of bias in ORO quantification.
Evolutionary Biology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the bias and artifact problems existing in the existing Oil Red O (ORO) staining quantification methods. These problems make these methods unable to accurately detect small differences in lipid content. Specifically: 1. **Visual scoring method**: It relies on subjective judgment and is prone to introduce human errors. 2. **Manual adjustment of analysis parameters**: Differences between different operators may lead to inconsistent results. 3. **Image format problems**: Some image formats will damage pixel intensity values and affect the quantification accuracy. 4. **Spectral absorption measurement bias**: Traditional methods quantify ORO staining by calculating the transmittance difference between red light (ORO - transparent) and blue - green light (ORO - absorbed), but do not consider the response differences of the imaging system in different spectral ranges. To solve these problems, the authors proposed a method based on filter collection and semi - automatic image processing, including steps such as background intensity correction, to eliminate multiple potential sources of bias, thereby achieving more accurate ORO staining quantification. ### Method overview - **Staining and sample preparation**: - Use a modified ORO staining method to stain nematodes. - Include steps such as fixation, dehydration, staining, and mounting. - **Image acquisition**: - Use a microscope system equipped with a monochrome camera to obtain multi - channel images through specific filters. - Ensure that the lamp intensity, exposure time, objective lens, and filter settings are consistent to avoid image saturation. - **Image analysis**: - Use the custom script `ORO_measure2.ijm` in Fiji software for automated analysis. - Mark the background area to correct the spectral response differences between different channels. - Manually outline the nematode contour and calculate the average intensity, integrated density, and median intensity of each nematode ROI. ### Results and discussion Through the above - mentioned method, the authors can effectively reduce the bias caused by the spectral response differences of the imaging system and ensure reliable results even in the case of small changes in lipid content. The experimental results show that when using an LED light source, the correction factor can keep the ratio between the two channels constant, further improving the quantification accuracy. In conclusion, this method is suitable for evaluating significant and subtle lipid metabolism differences, especially in cases where high - precision quantification is required.