A workflow for targeted proteomics assay development using a versatile linear ion trap

Ariana E Shannon,Rachael N Teodorescu,No joon Song,Lilian R Heil,Cristina C Jacob,Philip M Remes,Mark P Rubinstein,Brian C Searle
DOI: https://doi.org/10.1101/2024.05.31.596891
2024-06-01
Abstract:Advances in proteomics and mass spectrometry have enabled the study of limited cell populations, such as single-cell proteomics, where high-mass accuracy instruments are typically required. While triple quadrupoles offer fast and sensitive nominal resolution measurements, these instruments are effectively limited to targeted proteomics. Linear ion traps (LITs) offer a versatile, cost-effective alternative capable of both targeted and global proteomics. We demonstrate a workflow using a newly released, hybrid quadrupole-LIT instrument for developing targeted proteomics assays from global data-independent acquisition (DIA) measurements without needing high-mass accuracy. Gas-phase fraction-based DIA enables rapid target library generation in the same background chemical matrix as each quantitative injection. Using a new software tool embedded within EncyclopeDIA for scheduling parallel reaction monitoring assays, we show consistent quantification across three orders of magnitude of input material. Using this approach, we demonstrate measuring peptide quantitative linearity down to 25x dilution in a background of only a 1 ng proteome without requiring stable isotope labeled standards. At 1 ng total protein on column, we found clear consistency between immune cell populations measured using flow cytometry and immune markers measured using LIT-based proteomics. We believe hybrid quadrupole-LIT instruments represent an economic solution to democratizing mass spectrometry in a wide variety of laboratory settings.
Biochemistry
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to develop a workflow for targeted proteomics analysis using a Linear Ion Trap (LIT), especially the ability to perform high - precision quantitative measurements in low - input samples. Specifically, the researchers hope to answer the following three questions: 1. **Instrument performance**: After removing the high - resolution Orbitrap, can a more economical Quadrupole - Linear Ion Trap (Q - LIT) mass spectrometer be used as an independent instrument for both library generation and targeted proteomics measurements? 2. **Quantitative ability of low - input samples**: Can the Q - LIT mass spectrometer quantify peptides at the single - cell level or with even lower sample amounts? 3. **Measurement of biologically relevant proteins**: In quantitative experiments, can biologically relevant proteins at the level of 1 ng or lower be measured? To answer these questions, the researchers used the newly released Stellar Q - LIT mass spectrometer from Thermo Fisher Scientific to evaluate its quantitative linearity in whole - proteome library generation, targeted Parallel Reaction Monitoring (PRM) experiments, as well as its sensitivity and measurement consistency in a biological context. Through these experiments, they demonstrated the application potential of Q - LIT in low - input samples. Especially for laboratories with limited resources, Q - LIT provides a cost - effective solution.