Noninvasive time-lapse 3D subcellular analysis of embryo development for machine learning-enabled prediction of blastocyst formation

Chungha Lee,Geon Kim,Taeseop Shin,Sangho Lee,Jae Young Kim,Kyoung Hee Choi,Jieun Do,Jaehyeong Park,Jaephil Do,Ji Hyang Kim,YongKeun Park
DOI: https://doi.org/10.1101/2024.05.07.592317
2024-05-08
Abstract:In developmental biology and in vitro fertilization (IVF), image-based assessment of embryos is pivotal. Traditional methods in clinical IVF have been constrained to 2D morpho-kinetic profiling and manual selection, hindered by the absence of noninvasive techniques for quantitative 3D imaging over extended durations. Here, we overcome these limitations by employing low-coherence holotomography to monitor mouse preimplantation embryo development from the 2-cell stage to the expanded blastocyst. This approach enables the generation of 3D refractive index tomograms of unlabeled embryos, facilitating the observation of subcellular developmental dynamics. We investigated the 3D spatiotemporal profiles of embryo development, identifying key morpho-kinetic parameters that distinguish between embryos with differing developmental outcomes—specifically, Grade A embryos that successfully progressed to expanded blastocysts within 72 hours, and Grade C embryos that did not. Using machine learning, we demonstrate the 3D morpho-kinetic parameters can offer a noninvasive, quantitative framework for predicting embryos with high developmental potential.
Developmental Biology
What problem does this paper attempt to address?
The paper attempts to address the problem of how to accurately assess the quality of embryos in assisted reproductive technologies (such as in vitro fertilization, IVF) through non-invasive methods, particularly how to predict which embryos have higher developmental potential and can successfully form blastocysts. Specifically, traditional methods mainly rely on 2D morphological assessment, which has the following limitations: 1. **Lack of high-resolution 3D imaging**: Existing non-invasive techniques cannot provide high-resolution optical slices of the entire embryo, limiting detailed observation of the internal structure of the embryo. 2. **Subjectivity of manual selection**: Traditional embryo assessment methods rely on manual selection, which is easily influenced by subjective factors. 3. **Lack of dynamic changes**: 2D morphological assessment cannot capture the dynamic process of embryo development, thus affecting the comprehensive evaluation of embryo quality. To address these issues, the study employed low-coherence holotomography (HT) technology combined with machine learning methods to achieve 3D label-free, high-resolution, long-term continuous imaging of mouse embryos from the 2-cell stage to the expanded blastocyst stage. Through this method, researchers were able to generate 3D refractive index tomograms of unlabeled embryos, observe subcellular level developmental dynamics, and identify key morphological dynamic parameters that distinguish embryos with different developmental outcomes. Ultimately, the study proposed a non-invasive, quantitative framework based on 3D morphological dynamic parameters to predict embryos with high developmental potential.