Seq-Scope Protocol: Repurposing Illumina Sequencing Flow Cells for High-Resolution Spatial Transcriptomics

Yongsung Kim,Weiqiu Cheng,Chun-Seok Cho,Yongha Hwang,Yichen Si,Anna Park,Mitchell Schrank,Jer-En Hsu,Jingyue Xi,Myungjin Kim,Ellen Pedersen,Olivia I. Koues,Thomas Wilson,Goo Jun,Hyun Min Kang,Jun Hee Lee
DOI: https://doi.org/10.1101/2024.03.29.587285
2024-04-01
Abstract:Spatial transcriptomics (ST) technologies represent a significant advance in gene expression studies, aiming to profile the entire transcriptome from a single histological slide. These techniques are designed to overcome the constraints faced by traditional methods such as immunostaining and RNA hybridization, which are capable of analyzing only a few target genes simultaneously. However, the application of ST in histopathological analysis is also limited by several factors, including low resolution, a limited range of genes, scalability issues, high cost, and the need for sophisticated equipment and complex methodologies. Seq-Scope—a recently developed novel technology—repurposes the Illumina sequencing platform for high-resolution, high-content spatial transcriptome analysis, thereby overcoming these limitations. Here we provide a detailed step-by-step protocol to implement Seq-Scope with an Illumina NovaSeq 6000 sequencing flow cell that allows for the profiling of multiple tissue sections in an area of 7 mm × 7 mm or larger. In addition to detailing how to prepare a frozen tissue section for both histological imaging and sequencing library preparation, we provide comprehensive instructions and a streamlined computational pipeline to integrate histological and transcriptomic data for high-resolution spatial analysis. This includes the use of conventional software tools for single cell and spatial analysis, as well as our recently developed segmentation-free method for analyzing spatial data at submicrometer resolution. Given its adaptability across various biological tissues, Seq-Scope establishes itself as an invaluable tool for researchers in molecular biology and histology.
Genomics
What problem does this paper attempt to address?
The main problems that this paper attempts to solve are the limitations of existing spatial transcriptomics techniques in terms of resolution, throughput, cost, and complexity. Specifically: 1. **Low resolution**: Existing spatial transcriptomics techniques, such as the Visium platform of 10x Genomics, have a resolution of only 100 μm, which is lower than the resolving power of the human eye (40 μm). Although some new techniques, such as bead arrays or microfluidic techniques, have increased the resolution to 10 - 20 μm, they still do not reach the precision of traditional optical microscopes. 2. **Limited throughput**: High - resolution spatial transcriptomics techniques usually require complex staining/imaging processes and a large amount of computational image analysis, which limits the number of genes analyzed simultaneously and the time efficiency. 3. **High cost**: High - resolution spatial transcriptomics techniques usually require expensive equipment and complex experimental steps, resulting in high costs. 4. **High complexity**: These techniques usually require specialized equipment and complex experimental methods, limiting their application in ordinary laboratories. To solve these problems, the paper introduces a new technique named Seq - Scope, which re - utilizes the flow cell of the Illumina sequencing platform to achieve high - resolution, high - throughput, low - cost, and easy - to - use spatial transcriptomics analysis. The specific advantages of Seq - Scope include: - **Sub - micrometer - level resolution**: Seq - Scope can provide a center - to - center resolution of 0.5 - 0.7 μm, which is the highest resolution among currently available sequencing - based spatial transcriptomics techniques. - **High capture efficiency**: Seq - Scope has achieved a capture efficiency of more than 23 UMIs per square micrometer in the colon dataset. - **Utilizes the Illumina sequencing platform**: Seq - Scope utilizes the widely - used Illumina sequencing platform, ensuring high fidelity and reliability. - **Easy access to materials**: The required reagents and consumables are commercially readily available. - **Accurate histopathological annotation**: The transparent Illumina flow cell makes Seq - Scope compatible with multiple histological methods, such as HE staining, and can precisely align histological images and spatial transcriptome data through markers pre - engraved on the surface of the flow cell. - **Simplified computational analysis**: It provides a simplified computational analysis process and generates a digital gene expression matrix that can be used for single - cell and spatial analysis. - **Fast turnaround and scalability**: The design of Seq - Scope allows a single technician to process multiple samples simultaneously, with excellent scalability. - **Cost - effectiveness**: Using the NovaSeq 6000 flow cell, the cost of Seq - Scope is much lower than that of other high - resolution spatial transcriptomics techniques, such as 10x Visium. - **Versatility and potential for future development**: Seq - Scope is not only suitable for current transcriptomics research but also provides a platform for future multi - omics analysis and other applications. Through these improvements, Seq - Scope provides researchers with a powerful tool that can achieve high - resolution spatial transcriptomics analysis in molecular biology and histological research.