Two serial filters determine P2X7R cation selectivity, Ser342 in the central pore and lateral acidic residues at the cytoplasmic interface

Fritz Markwardt,Eike Schön,Michaela Raycheva,Aparna Malisetty,Sanaria Hawro Yakoob,Malte Berthold,Günther Schmalzing
DOI: https://doi.org/10.1101/2024.02.19.579953
2024-02-19
Abstract:The human P2X7R (hP2X7R) is a homotrimeric cell surface receptor gated by extracellular ATP with two transmembrane helices per subunit, TM1 and TM2. A ring of three S342 residues, one from each pore-forming TM2 helix, located halfway across the membrane bilayer, functions to close and open the gate in the apo and ATP bound open states, respectively. The hP2X7R is selective for small inorganic cations, but can also conduct larger organic cations such as Tris . Here, we show by voltage-clamp electrophysiology in oocytes that mutation of S342 residues to positively charged lysines decreases the selectivity for Na over Tris , but maintains cation selectivity. Deep in the membrane, laterally below the S342 ring are nine acidic residues arranged as an isosceles triangle consisting of residues E14, D352, and D356 on each side, which do not move significantly during gating. When the E14K mutation is combined with lysine substitutions of D352 and/or D356, cation selectivity is lost and permeation of the small anion Cl is allowed. Lysine substitutions of S342 together with D352 or E14 plus D356 in the acidic triangle convert the hP2X7R mutant to a fully Cl -selective ATP -gated receptor. We conclude that the ion selectivity of wild-type hP2X7R is determined by two sequential filters in one single pathway: ( ) a primary size filter, S342, in the membrane center and ( ) three cation filters lateral to the channel axis, one per subunit interface, consisting of a total of nine acidic residues at the cytoplasmic interface.
Biophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: How does the human P2X7 receptor (hP2X7R) selectively allow specific ions to pass through its channel? Specifically, the researchers explored how two consecutive filtering mechanisms jointly determine the selectivity of hP2X7R for small inorganic cations, and how these mechanisms affect the selectivity of the channel after mutation. ### Background and Problem of the Paper The P2X7 receptor is a cation - selective channel activated by extracellular ATP, widely existing in immune cells and playing an important role in the inflammatory response. This receptor can selectively pass small inorganic cations (such as Na+, K+ and Ca2+), and also allows some larger organic cations (such as Tris+) to pass. However, the specific mechanisms by which the P2X7 receptor achieves this selectivity are not fully understood. ### Research Objectives 1. **Determine the Selective Filtering Mechanisms**: The researchers hope to determine which structural features in hP2X7R determine its selectivity for different ions. 2. **Explore the Effects of Mutations**: By mutating key amino acid residues, the researchers hope to understand how these mutations change the selectivity of the channel, especially whether a cation - selective channel can be transformed into an anion - selective channel. ### Main Findings 1. **The S342 Loop as the Main Size Filter**: The S342 loop (the loop formed by three S342 residues) located at the center of the membrane mainly functions as a size filter, restricting the passage of larger ions (such as Tris+). 2. **The Acidic Triangle as a Charge Filter**: Nine acidic residues (three at each subunit interface, forming an isosceles triangle) located at the membrane - cytoplasmic interface constitute a charge filter, further enhancing the selectivity for cations. 3. **Mutation Effects**: - **S342K Mutation**: Mutating S342 to lysine (S342K) will reduce the selectivity of Na+ relative to Tris+, but still maintain cation selectivity. - **E14K, D352K and D356K Mutations**: When these acidic residues are mutated to lysine, especially when E14K is combined with D352K or D356K, the channel loses its cation selectivity and allows small anions (such as Cl -) to pass. ### Conclusions The researchers conclude that the selectivity of hP2X7R is jointly determined by two consecutive filtering mechanisms: 1. **Size Filter**: The S342 loop located at the center of the membrane mainly restricts the passage of larger ions. 2. **Charge Filter**: The acidic triangle located at the membrane - cytoplasmic interface enhances the selectivity for cations through electrostatic interactions. These findings not only enhance the understanding of the function of the P2X7 receptor, but also provide an important structural basis for the development of drugs targeting this receptor.