Atacama Clear for Complex 3D Imaging of Organs

Neranjan de Silva,Lauretta A. Lacko,Edgar A. Jamies,Todd Evans,Romulo Hurtado
DOI: https://doi.org/10.1101/2024.01.22.576689
2024-01-23
Abstract:3D reconstructive imaging is a powerful strategy to interrogate the global architecture of tissues. We developed Atacama Clear (ATC), a novel method that increases 3D imaging signal-to-noise ratios (SNRs) while simultaneously increasing the capacity of tissue to be cleared. ATC potentiated the clearing capacity of all tested chemical reagents currently used for optical clearing by an average of 68%, and more than doubled SNRs. This increased imaging efficacy enabled multiplex interrogation of tough fibrous tissue and specimens that naturally exhibit high levels of background noise, including the heart, kidney, and human biopsies. Indeed, ATC facilitated visualization of previously undocumented adjacent nephron segments that exhibit notoriously high autofluorescence, elements of the cardiac conduction system, and the distinct human glomerular tissue layers, at single cell resolution. Moreover, ATC was validated to be compatible with fluorescent reporter proteins in murine, zebrafish, and 3D stem cell model systems. These data establish ATC for 3D imaging studies of challenging tissue types.
Molecular Biology
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to improve the signal - to - noise ratio (SNR) of 3D imaging technology in processing tissues with high autofluorescence and difficult to be cleared (such as the heart and kidneys), while increasing the clearing ability of these tissues. Specifically, the authors developed a new method named Atacama Clear (ATC), aiming at: 1. **Reducing tissue autofluorescence**: Through the use of Atacama - H₂O₂ (AT - HP) treatment, the tissue autofluorescence was significantly reduced, thereby improving the signal - to - noise ratio of imaging. 2. **Enhancing tissue clearing ability**: AT - HP not only reduced autofluorescence but also enhanced the clearing effects of various known clearing reagents, with an average 68% increase in clearing ability. 3. **Achieving high - resolution 3D imaging**: ATC enables researchers to perform multiplex 3D imaging on complex tissues such as the heart and kidneys, and to observe previously unrecorded tissue structures such as renal tubule segments, the cardiac conduction system, and different glomerular tissue layers in human kidney biopsies at single - cell resolution. ### Specific problems and solutions 1. **High autofluorescence problem**: - **Solution**: Using AT - HP to treat tissues effectively reduced the tissue autofluorescence. Experimental results showed that the autofluorescence of kidney and heart tissues after AT - HP treatment was reduced by 57% and 83% respectively. 2. **Insufficient clearing ability**: - **Solution**: AT - HP enhanced the clearing effects of various clearing reagents, with an average 68% increase in clearing ability. In addition, using AT - OC (a refractive index - matching solution composed of formamide and glycerol) further enhanced tissue clearing. 3. **Multiplex 3D imaging**: - **Solution**: By combining AT - HP and AT - OC, ATC can achieve high - resolution multiplex 3D imaging in tissues with high autofluorescence and difficult to be cleared. For example, different parts of the cardiac conduction system and glomerular tissue layers in human kidney biopsies were successfully visualized. ### Experimental verification - **Kidney imaging**: ATC successfully visualized the 3D structures of renal tubule segments, including connecting tubules and distal convoluted tubules, with a resolution reaching the single - cell level. - **Heart imaging**: ATC was able to clearly display key parts of the cardiac conduction system, such as the sinoatrial node (SAN), and maintained good signal strength in heart tissues as deep as 1.6 millimeters. - **Preservation of fluorescent proteins**: ATC is compatible with fluorescent reporter proteins, can effectively preserve and detect fluorescent signals, and is suitable for various experimental model systems, such as mice, zebrafish, and 3D stem cell models. In conclusion, this paper solves the key problems in 3D imaging of tissues with high autofluorescence and difficult to be cleared by developing the ATC method, providing new tools and techniques for high - resolution imaging of complex tissues.