A new method for removing artifacts from recordings of the electrically evoked compound action potential: Single-pulse stimulation

Jeffrey Skidmore,Yi Yuan,Shuman He
DOI: https://doi.org/10.1101/2024.01.17.24301435
2024-01-17
Abstract:This report presents a new method for removing electrical artifact contamination from the electrically evoked compound action potential (eCAP) evoked by single cathodic-leading, biphasic-pulse stimulation. The development of the new method is motivated by results recorded in human cochlear implant (CI) users showing that the fundamental assumption of the classic forward masking artifact rejection technique is violated in up to 45% of cases tested at high stimulation levels when using default stimulation parameters. Subsequently, the new method developed based on the discovery that a hyperbola best characterizes the artifacts created during stimulation and recording is described. The eCAP waveforms obtained using the new method are compared to those recorded using the classic forward masking technique. The results show that eCAP waveforms obtained using both methods are comparable when the fundamental assumption of the classic forward masking technique is met. In contrast, eCAP amplitudes obtained using the two methods are significantly different when the fundamental assumption of the classic forward masking technique is violated, with greater differences in the eCAP amplitude for greater assumption violations. The new method also has excellent test-retest reliability (Intraclass correlation > 0.98). Overall, the new method is a viable alternative to the classic forward masking technique for obtaining artifact-free eCAPs evoked by single-pulse stimulation in CI users.
Otolaryngology
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is the limitations of the existing forward masking technique (FwdMsk) in removing electrical artifacts in electrically evoked compound action potential (eCAP) recordings evoked by single - pulse stimulation in cochlear implant users (CI users). Specifically, the paper points out: 1. **The basic assumptions of the forward masking technique are often violated**: The forward masking technique relies on the masking pulse being able to drive neurons into the absolute refractory period so that they do not respond to the subsequent probe pulse. However, in up to 45% of the test cases, especially when using default stimulation parameters at high stimulation levels, this assumption does not hold. 2. **The problem of estimating the absolute refractory period (ARP)**: The traditional forward masking technique usually uses 400 microseconds as the mask - probe interval (MPI), but research shows that the ARP at many electrode positions is actually less than 400 microseconds, which leads to the failure of the forward masking technique in these cases. 3. **A new method is needed to remove artifacts**: Due to the above problems, the paper proposes a new method based on hyperbolic fitting (HyperFit) for more accurately removing electrical artifacts in eCAP recordings. ### Main features of the new method: - **Hyperbolic fitting**: The study found that the combined stimulation and recording artifact waveforms at a single electrode position can be best described by the hyperbolic function \(y = ax + b+\frac{c}{x + d}\). This function has a vertical asymptote \(x=-d\) and a slope asymptote \(y = ax + b\), which can well capture the rapid initial decay and the final linear asymptotic characteristics of the artifact waveform. - **Higher test - retest reliability**: The new method exhibits excellent test - retest reliability (intra - class correlation coefficient > 0.98) in multiple measurements. ### Conclusion: The hyperbolic fitting method (HyperFit) proposed in the paper is an effective alternative to the traditional forward masking technique, especially for removing electrical artifacts in eCAP recordings evoked by single - pulse stimulation. This method not only has results comparable to the traditional method when the basic assumptions hold, but also performs better when the assumptions are violated.