Non-Invasive Perfusion MR Imaging of the Human Brain via Breath-Holding

J.B. Schulman,S. Kashyap,S.G. Kim,K. Uludağ
DOI: https://doi.org/10.1101/2023.08.24.554712
2024-03-05
Abstract:Dynamic susceptibility contrast (DSC) MRI plays a pivotal role in the accurate diagnosis and prognosis of several neurovascular diseases, but is limited by its reliance on gadolinium, an intravascularly injected chelated metal. Here, we determined the feasibility of measuring perfusion using a DSC analysis of breath-hold-induced gradient-echo-MRI signal changes. We acquired data at both 3T and 7T from ten healthy participants who engaged in eight consecutive breath-holds. By pairing a novel arterial input function strategy with a standard DSC MRI analysis, we measured the cerebral blood volume, flow, and transit delay, and found values to agree with those documented in the literature using gadolinium. We also observed voxel-wise agreement between breath-hold and arterial spin labeling measures of cerebral blood flow. Breath-holding resulted in significantly higher contrast-to-noise (6.2 at 3T vs 8.5 at 7T) and gray matter-to-white matter contrast at higher field strength. Finally, using a simulation framework to assess the effect of dynamic vasodilation on perfusion estimation, we found global perfusion underestimation of 20-40%. For the first time, we have assessed the feasibility of and limitations associated with using breath-holds for perfusion estimation with DSC. We hope that the methods and results presented in this study will help pave the way toward contrast-free perfusion imaging, in both basic and clinical research.
Biophysics
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to develop a non - invasive brain perfusion imaging method, using the gradient - echo MRI signal changes induced by breath - holding to replace the traditional gadolinium - contrast - agent - based dynamic susceptibility - contrast (DSC) MRI technique. Specifically, the researchers aim to: 1. **Verify Feasibility**: Determine whether using breath - holding as a contrast mechanism can reliably measure perfusion parameters such as cerebral blood volume (CBV), cerebral blood flow (CBF) and mean transit time (MTT). 2. **Improve Signal - to - Noise Ratio**: Evaluate the contrast - to - noise ratio (CNR) caused by breath - holding and the contrast between gray matter and white matter at 3T and 7T magnetic field strengths, and compare the performance differences at different field strengths. 3. **Determination of Arterial Input Function (AIF)**: Develop a new method to select the arterial input function (AIF), which is a crucial step in DSC analysis for quantifying tissue perfusion. Since breath - holding does not directly change the deoxyhemoglobin concentration in the blood but affects the signal through vasodilation, a new method is required to determine the AIF. 4. **Verify Results**: Compare the perfusion parameters obtained by the breath - holding method with the results obtained by using other techniques (such as arterial spin - labeling ASL) to verify their consistency and accuracy. 5. **Evaluate Limitations**: Through simulation studies, evaluate the impact of vasodilation on the estimation of perfusion parameters, especially the degree of underestimation of CBV, so as to better understand the limitations and application scope of this method. In general, the goal of this paper is to explore a non - invasive brain perfusion imaging method without exogenous contrast agents, providing a new tool for clinical and basic research.