Deok-Hoon Jeong,Anezka Kvasnickova,Jean-Baptiste Boutin,David Cebron,Alban Sauret
Abstract:The withdrawal of a liquid or the translation of a liquid slug in a capillary tube leads to the deposition of a thin film on the inner wall. When particles or contaminants are present in the liquid, they deposit and contaminate the tube if the liquid film is sufficiently thick. In this article, we experimentally investigate the condition under which particles are deposited during the air invasion in a capillary tube initially filled with a dilute suspension. We show that the entrainment of particles in the film is controlled by the ratio of the particle and the tube radii and the capillary number associated with the front velocity. We also develop a model which suggests optimal operating conditions to avoid contamination during withdrawal of a suspension. This deposition mechanism can also be leveraged in coating processes by controlling the deposition of particles on the inner walls of channels.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the conditions for particle deposition on the inner wall when the diluted suspension in the capillary is invaded by air. Specifically, the study focused on whether particles would be entrained in the thin liquid film formed during the air - invasion process, and explored the key parameters controlling this process, such as the ratio of the particle to the capillary radius and the capillary number (Ca) related to the front - edge velocity. Through experiments and theoretical models, the authors aimed to determine the optimal operating conditions to avoid particle deposition, which is of great significance in fields such as liquid dispensing, pipe coating, and flow in porous media.
### Research Background
Multiphase fluid systems, involving liquid, gas, and solid particles, are ubiquitous in many practical applications, such as liquid dispensing, pipe coating, and flow in porous media. When the liquid contains particles or contaminants, if the formed thin liquid film is thick enough, these particles or contaminants will be deposited on the pipe wall, resulting in pollution. This paper experimentally studied the conditions for particle deposition when air invaded the capillary initially filled with a diluted suspension, and proposed a model to predict the optimal operating conditions to avoid pollution.
### Key Findings
1. **Particle Entrainment Conditions**: Whether particles can be entrained in the thin liquid film is mainly determined by the ratio of the particle radius to the capillary radius ($\frac{a}{R}$) and the capillary number ($Ca$). Specifically, the condition for particle entrainment is that the liquid film thickness $h^*$ at the stagnation point is greater than a certain proportion $\alpha a$ of the particle diameter, where $1\leq\alpha\leq2$.
2. **Theoretical Model**: Through theoretical analysis, the authors derived the relationship between the liquid film thickness $h^*$ at the stagnation point and the capillary number $Ca$:
\[
\frac{h^*}{R}=\frac{4.02 Ca^{2/3}}{1 + 3.35 Ca^{2/3}}
\]
This model can predict the experimental results quite well.
3. **Particle Entrainment Threshold**: Using the experimental data, the authors determined the relationship between the critical capillary number $Ca^*$ for particle entrainment and the ratio of the particle radius to the capillary radius:
\[
Ca^*=\left(\frac{\alpha}{4.02}\right)^{3/2}\left(\frac{a}{R}\right)^{3/2}
\]
where $\alpha = 1.15\pm0.1$.
### Experimental Methods
In the experiment, capillaries with different radii (500 μm, 750 μm, and 1000 μm) and polystyrene particles of different sizes (40 μm, 72 μm, and 125 μm) were used and carried out in silicone oil. By pumping the diluted suspension at a constant speed, it was observed whether the particles were entrained in the formed liquid film, and the relevant parameters were recorded.
### Conclusions
This study revealed the conditions for particles to be entrained in the liquid film when air invaded the capillary, and proposed a prediction model. These findings are of great guiding significance for optimizing liquid dispensing and pipe coating processes and avoiding pollution. In addition, this mechanism can also be used to control particle deposition on the inner wall of the channel, thereby optimizing the coating process.