Signal Separation Using a Mathematical Model of Physiological Signals for the Measurement of Heart Pulse Wave Propagation With Array Radar

Takuya Sakamoto
DOI: https://doi.org/10.1109/ACCESS.2020.3026539
2020-09-25
Abstract:The arterial pulse wave, which propagates along the artery, is an important indicator of various cardiovascular diseases. By measuring the displacement at multiple parts of the human body, pulse wave velocity can be estimated from the pulse transit time. This paper proposes a technique for signal separation using an antenna array, so that pulse wave propagation can be measured in a non-contact manner. The body displacements due to the pulse wave at different body parts are highly correlated, and cannot be accurately separated using techniques that assume independent or uncorrelated signals. The proposed method formulates the signal separation as an optimization problem, based on a mathematical model of the arterial pulse wave. The objective function in the optimization comprises four terms that are derived based on a small-displacement approximation, unimodal impulse response approximation, and a causality condition. The optimization process was implemented using a genetic algorithm. The effectiveness of the proposed method is demonstrated through numerical simulations and experiments.
Signal Processing
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a non - contact technique for measuring pulse wave propagation, especially to achieve the measurement of pulse wave velocity (PWV) by using an antenna array. Traditional PWV measurement methods usually require the installation of multiple contact sensors at different parts of the body. This not only restricts the freedom of movement of the measured person, but may also cause discomfort and is not suitable for long - term continuous monitoring. This paper proposes a signal separation technique based on a mathematical model, aiming to overcome these limitations and achieve unconstrained, non - contact pulse wave propagation measurement. Specifically, this research focuses on how to accurately separate the skin displacement signals caused by the pulse wave from the radar echo. These signals are highly correlated between different parts of the body, but there are time differences corresponding to the pulse transit time (PTT). Due to the correlation of these signals, traditional separation techniques that assume the signals are independent or uncorrelated are not applicable. For this reason, the paper proposes a new method, formulating the signal separation problem as an optimization problem. The optimization problem constructs the objective function based on the small - displacement approximation of the arterial pulse wave, the single - mode impulse response approximation and the causality condition. The optimization process is implemented using a genetic algorithm, and the effectiveness of the proposed method is verified by numerical simulation and experiments.