Nearly-incompressible transverse isotropy (NITI) of cornea elasticity: model and experiments with acoustic micro-tapping OCE

John J Pitre Jr,Mitchell A Kirby,David S Li,Tueng T Shen,Ruikang K Wang,Matthew O'Donnell,Ivan Pelivanov
DOI: https://doi.org/10.48550/arXiv.2006.10893
2020-06-19
Abstract:The cornea provides the largest refractive power for the human visual system. Its stiffness, along with intraocular pressure (IOP), are linked to several pathologies, including keratoconus and glaucoma. Although mechanical tests can quantify corneal elasticity ex vivo, they cannot be used clinically. Optical coherence elastography (OCE), which launches and tracks shear waves to estimate stiffness, provides an attractive non-contact probe of corneal elasticity. To date, however, OCE studies report corneal moduli around tens of kPa, orders-of-magnitude less than those (few MPa) obtained by tensile/inflation testing. This large discrepancy impedes OCE's clinical adoption. Based on corneal microstructure, we introduce and fully characterize a nearly-incompressible transversally isotropic (NITI) model depicting corneal biomechanics. We show that the cornea must be described by two shear moduli, contrary to current single-modulus models, decoupling tensile and shear responses. We measure both as a function of IOP in ex vivo porcine cornea, obtaining values consistent with both tensile and shear tests. At pressures above 30 mmHg, the model begins to fail, consistent with non-linear changes in cornea at high IOP.
Biological Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **How to accurately measure the biomechanical properties of the cornea, especially its elastic modulus, through optical coherence elastography (OCE) technology, and resolve the large differences among current measurement methods**. ### Background and Problem Description 1. **Importance of the Biomechanical Properties of the Cornea** - The cornea is one of the most important refractive components in the human eye visual system, and its stiffness and intraocular pressure (IOP) are related to various pathological states (such as keratoconus and glaucoma). - Currently, mechanical tests can quantify the elastic modulus of the cornea, but these methods can only be performed in vitro and cannot be used for clinical applications. 2. **Advantages and Challenges of OCE Technology** - OCE technology estimates the stiffness of tissues by exciting and tracking shear waves, providing a non - contact method for measuring corneal elasticity. - However, the corneal modulus (tens of kPa) reported in existing OCE studies is much lower than the modulus obtained through tensile or inflation tests (several MPa). This large difference hinders the clinical application of OCE. 3. **Limitations of Existing Models** - Most current corneal mechanics studies assume that the cornea is a nearly incompressible isotropic linearly elastic solid, and only one elastic parameter (Young's modulus \( E \) or shear modulus \( \mu=\frac{E}{3} \)) is used to describe the stiffness. - This single - parameter model cannot explain the large stiffness differences exhibited by the cornea under different loading methods. ### Main Contributions of the Paper 1. **Introduction of the NITI Model** - Based on the microstructure of the cornea, the authors propose and fully characterize a nearly incompressible transverse anisotropy (NITI) model to more accurately describe the biomechanical behavior of the cornea. - The NITI model assumes that the cornea requires two shear moduli (\( G \) and \( \mu \)) to describe the tensile and shear responses respectively, thereby decoupling these two mechanical behaviors. 2. **Experimental Verification** - The authors used acoustic micro - tapping (AµT) OCE technology to measure the changes of these two moduli with IOP in vitro porcine corneas and obtained results consistent with tensile and shear tests. - The experimental results show that the model begins to fail at pressures above 30 mmHg, which is consistent with the nonlinear changes of the cornea at high IOP. ### Conclusions - By introducing the NITI model, the authors have successfully resolved the large differences between OCE measurement results and traditional mechanical test results. - This model not only improves the accuracy of OCE measurements but also provides a theoretical basis for further clinical applications. - Future research needs to further verify the applicability of this model to the human cornea and explore the complex anisotropic behavior at higher IOP.