Coherent anti-Stokes Raman scattering through thick biological tissues by single wavefront shaping

Matthias Hofer,Siddarth Shivkumar,Bilal El Waly,Sophie Brasselet
DOI: https://doi.org/10.1103/PhysRevApplied.14.024019
2020-03-08
Abstract:Coherent Anti Stokes Raman Scattering (CARS) offers many advantages for nonlinear bio-imaging, thanks to its sub-cellular spatial resolution and unique chemical specificity. Its working principle requires two incident pulsed laser beams with distinct frequencies to be focused in space and time, which focus quality however rapidly deteriorates when propagating at large depths in biological tissues. The depth limits of CARS and the capability of wavefront correction to overcome these limits are currently unknown. In this work we exploit the spectral correlation properties of the transmission matrix of a scattering medium in a pulsed regime, to recover coherent focusing for two distant incident CARS wavelengths which propagation is initially uncorrelated. Using wavefront shaping with a single spatial light modulator, we recover CARS generation through thick mice spinal cord tissues where initially no signal is measurable due to scattering, and demonstrate point scanning over large field of views of tens of micrometers.
Optics,Biological Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: to achieve coherent anti - Stokes Raman scattering (CARS) imaging in thick biological tissues. Specifically, CARS imaging requires two pulsed laser beams with different frequencies to overlap spatially and temporally to produce a nonlinear interaction. However, when the light beams propagate in thick biological tissues, due to the scattering effect, the focal quality deteriorates rapidly, resulting in a significant attenuation of the CARS signal or even making it undetectable. To solve this problem, the authors propose a method based on single - wavefront shaping. By manipulating the transmission matrix (TM), the coherent focusing between the pump light and Stokes light of two different wavelengths is restored, thereby generating CARS signals in thick biological tissues. The key to this method lies in utilizing the transmission matrix characteristics of the scattering medium to perform wavefront shaping under broadband conditions. This enables the restoration of coherence and spatial overlap even when the two light beams initially present a random and uncorrelated speckle pattern, and further enables the generation of CARS signals. The following are the specific problems solved by the paper: 1. **The depth limitation of CARS imaging in thick biological tissues**: - Traditional CARS imaging is affected by the scattering effect in thick biological tissues, resulting in a sharp attenuation of the signal. - The method proposed in the paper can restore CARS signals in biological tissues as thick as several hundred micrometers, breaking through the previous depth limitations. 2. **Coherent focusing in a multi - scattering environment**: - In a multi - scattering environment, the phase and direction information of the light beams is lost, making it difficult to achieve the coherent superposition of the pump light and Stokes light. - By measuring and using the transmission matrix, the two light beams can be refocused behind the scattering medium to ensure their spatial and temporal overlap. 3. **Coherent control of light beams with different wavelengths**: - The pump light and Stokes light have different wavelengths and different propagation paths, resulting in significant differences in their behaviors in the scattering medium. - The paper proposes several strategies (such as using intermediate wavelengths, combining transmission matrices, etc.) to balance the focusing effects of the two wavelengths and ensure the effective generation of CARS signals. 4. **Large - field - of - view scanning ability**: - To achieve point - scanning imaging with a large field of view in thick biological tissues, exceeding the angular memory effect limitations of traditional methods. - By predicting the transmission matrix, high - resolution point - scanning can be performed on the sample exit plane to obtain high - quality CARS images. In summary, this paper aims to overcome the depth limitations and coherent focusing problems in CARS imaging in thick biological tissues through innovative wavefront - shaping techniques and transmission matrix measurements, thereby providing new solutions for chemical - specific imaging of deep - layer biological tissues.