Abstract:Aims Although cardiopulmonary exercise testing (CPET) is the gold standard to assess exercise capacity, simpler tests (i.e., 6‐min walk test, 6MWT) are also commonly used. The aim of this study was to evaluate the relationship between cardiorespiratory parameters during CPET and 6MWT in a large, multicentre, heterogeneous population. Methods We included athletes, healthy subjects, and heart failure (HF) patients of different severity, including left ventricular assist device (LVAD) carriers, who underwent both CPET and 6MWT with oxygen consumption measurement. Results We enrolled 186 subjects (16 athletes, 40 healthy, 115 non‐LVAD HF patients, and 15 LVAD carriers). CPET‐peakV̇O2 was 41.0 [35.0–45.8], 26.2 [23.1–31.0], 12.8 [11.1–15.3], and 15.2 [13.6–15.6] ml/Kg/min in athletes, healthy, HF patients, and LVAD carriers, respectively (P