Sloshing Load and Safety Assessment of Onshore LNG Storage Tank under Seismic Leakage Condition

Dong-ju Lee,S. Shin,Eon Kim
2016-06-26
Abstract:The purpose of this study is to identify the design sloshing load and evaluate the structural safety of the sprayed polyurethane foam (PUF) with density of 45 kg/m 3 , which is applied as an insulation material of full containment onshore LNG storage tank, under the seismic leakage condition. To do this, first, the design sloshing load was evaluated as per relevant design codes and the fluid structure interaction (FSI) simulations under the seismic load corresponding to the safety shutdown earthquake-aftershock (SSE aft ) after the inner tank leakage. From the result, the design drop height corresponding to the design sloshing load was determined through a series of preliminary wet drop tests. And then, the sloshing safety assessment of PUF was carried out using the wet drop test and simulation under the defined design drop height. Here, the wet drop simulations were performed using the established PUF material model by static and dynamic material tests and FSI simulation technique. Based on the results of the extensive wet drop tests and simulations with the design sloshing pressure, it was verified that the PUF sprayed inside the outer tank in the LNG storage tank considered has a sufficient structural safety under the design sloshing load caused by the LNG leakage and seismic load of SSE-aftershock.
Environmental Science,Engineering
What problem does this paper attempt to address?