A 0.6V 785-nW Multimodal Sensor Interface IC for Ozone Pollutant Sensing and Correlated Cardiovascular Disease Monitoring

Rishika Agarwala,Peng Wang,Henry L. Bishop,Anjana Dissanayake,Benton H. Calhoun
DOI: https://doi.org/10.1109/jssc.2021.3057229
2021-04-01
Abstract:In this article, we present the design and analysis of a 785-nW multimodal sensor interface IC for ozone pollutant sensing and correlated cardiovascular disease monitoring based on electrocardiography (ECG) and photoplethysmography (PPG). The proposed hybrid $dc$ offset current cancellation (DCOC) along with a 4- $text{M}Omega $ gain-regulated cascode transimpedance amplifier (RGC-TIA) enable PPG readout power reduction by $37times $ , compared with the state-of-the-art PPG sensor interfaces. The ozone sensing channel proposes an adaptive architecture to enable low $V_{text {DD}}$ operation, achieving a $300times $ power reduction, compared with the state-of-the-art gas sensing readouts. The ozone sensing channel's performance was also verified using custom resistive metal-oxide sensors for concentrations from 50 to 900 ppb. The sensor interface IC is fabricated in a 65-nm CMOS, integrating a 165-nW voltage-mode ECG channel, a 532-nW current-mode PPG channel, 76-nW resistive-mode ozone channel, and 12.6-nW peripheral circuits, all at 0.6 V. The total system power consumption including the LED and a custom digital readout IC is 10.98– $15.51~mu text{W}$ , which is $41times $ – $57times $ less than prior ozone/CVD joint monitoring sensor interface systems.
engineering, electrical & electronic
What problem does this paper attempt to address?