Characterization of Quantitative Susceptibility Mapping in the Left Ventricle of the Myocardium

Andrew Tyler,Li Huang,Karl Kunze,Radhouene Neji,Ronald Mooiweer,Charlotte Rogers,Pier Giorgio Masci,Sébastien Roujol
DOI: https://doi.org/10.1016/j.jocmr.2024.101000
IF: 6.4
2024-01-01
Journal of Cardiovascular Magnetic Resonance
Abstract:BACKGROUND: Myocardial quantitative susceptibility mapping (QSM) may offer better specificity to iron than conventional T<sub>2</sub>* imaging in the assessment of cardiac diseases, including intra-myocardial haemorrhage. However, the precision and repeatability of cardiac QSM has not yet been characterized. The aim of this study is to characterize these key metrics in a healthy volunteer cohort and show the feasibility of the method in patients.METHODS: Free breathing respiratory-navigated multi-echo 3D gradient echo (GRE) images were acquired, from which QSM maps were reconstructed using the MEDI toolbox. This technique was first evaluated in a susceptibility phantom containing tubes with known concentrations of gadolinium. In vivo characterization of myocardial QSM were then performed in a cohort of 10 healthy volunteers where each subject was scanned twice. Mean segment susceptibility, precision (standard deviation of voxel magnetic susceptibilities within one segment), and repeatability (absolute difference in segment mean susceptibility between repeats) of QSM were calculated for each AHA myocardial segment. Finally, the feasibility of the method was shown in ten patients, including four with haemorrhagic infarcts.RESULTS: The phantom experiment showed a strong linear relationship between measured and predicted susceptibility shifts (R<sup>2</sup> &gt; 0.99). For the healthy volunteer cohort, AHA segment analysis showed the mean segment susceptibility was 0.00 ± 0.02 ppm, the mean precision was 0.05 ± 0.04 ppm, and the mean repeatability was 0.02 ± 0.02 ppm. Cardiac QSM was successfully performed in all patients. Focal iron deposits were successfully visualized in the patients with haemorrhagic myocardial infarctions.CONCLUSION: The precision and repeatability of cardiac QSM were successfully characterized in phantom and in vivo experiments. The feasibility of the technique was also successfully demonstrated in patients. While challenges still remain, further clinical evaluation of the technique is now warranted.TRIAL REGISTRATION: This work does not report on a health care intervention.
radiology, nuclear medicine & medical imaging,cardiac & cardiovascular systems
What problem does this paper attempt to address?