Assessing anatomical variations of the inferior mesenteric artery via three-dimensional CT angiography and laparoscopic colorectal surgery: a retrospective observational study

Yuanyi Ding,Botian Zhao,Wenbo Niu,Xuhua Hu,Chenhui Li,Zining Liu,Bin Yu
DOI: https://doi.org/10.1038/s41598-024-57661-3
IF: 4.6
2024-03-26
Scientific Reports
Abstract:To assess the anatomy of the inferior mesenteric artery (IMA) and its branches by reviewing laparoscopic left-sided colorectal cancer surgery videos and comparing them with preoperative three-dimensional computed tomography (3D-CT) angiography, to verify the accuracy of 3D-CT vascular reconstruction techniques. High-definition surgical videos and preoperative imaging data of 200 patients who underwent laparoscopic left-sided colorectal cancer surgery were analysed, and the alignment of the IMA and its branches in relation to the inferior mesenteric vein (IMV) was observed and summarized. The above two methods were used to measure the length of the IMA and its branches. Of 200 patients, 47.0% had the sigmoid arteries (SAs) arise from the common trunk with the superior rectal artery (SRA), and 30.5% had the SAs arise from the common trunk with the left colic artery (LCA). In 3.5% of patients, the SAs arising from both the LCA and SRA. The LCA, SA, and SRA emanated from the same point in 13.5% of patients, and the LCA was absent in 5.5% of patients. The range of D cm (IMA length measured by intraoperative silk thread) and d cm (IMA length measured by 3D-CT vascular reconstruction) in all cases was 1.84–6.62 cm and 1.85–6.52 cm, respectively, and there was a significant difference between them. (p < 0.001). The lengths between the intersection of the LCA and IMV measured intraoperatively were 0.64–4.29 cm, 0.87–4.35 cm, 1.32–4.28 cm and 1.65–3.69 cm in types 1A, 1B, 1C, and 2, respectively, and there was no significant difference between the groups (p = 0.994). There was only a significant difference in the length of the IMA between the 3D-CT vascular reconstruction and intraoperative observation data, which can provide guidance to surgeons in preoperative preparation.
multidisciplinary sciences
What problem does this paper attempt to address?
The problems that this paper attempts to solve mainly focus on evaluating and validating the accuracy and practicality of 3D - CT vascular reconstruction technology in predicting the anatomical variations of the inferior mesenteric artery (IMA) and its branches. Specifically, the study retrospectively analyzed the high - definition surgical videos of 200 patients who underwent laparoscopic left - sided colorectal cancer surgery and the preoperative 3D - CT angiography data, and compared the differences between these two methods in measuring the length of IMA and the branching pattern to verify the accuracy of 3D - CT vascular reconstruction technology. ### Research Background With the increasing incidence of colorectal cancer, laparoscopic techniques are more and more widely used in gastrointestinal tumor surgeries. When performing laparoscopic radical resection of left - sided colorectal cancer, the ligation of IMA is an important step, but the choice of ligation location varies according to surgical requirements, the proficiency of surgeons, and the understanding of the anatomical relationship between blood vessels and nerves. Currently, there is still controversy regarding the advantages and disadvantages of high - level ligation of IMA (ligation at the origin from the aorta) and low - level ligation (ligation below the origin of the left colic artery (LCA)). Different ligation locations may affect the overall quality of the surgery and the prognosis of patients. ### Research Objectives 1. **Evaluate the anatomical variations of IMA and its branches**: Analyze the anatomical patterns of IMA and its branches by reviewing laparoscopic left - sided colorectal cancer surgery videos and preoperative 3D - CT angiography data. 2. **Verify the accuracy of 3D - CT vascular reconstruction technology**: Compare the differences between the two methods in measuring the length of IMA and the branching pattern to verify the accuracy and practicality of 3D - CT vascular reconstruction technology. ### Main Findings 1. **Classification of IMA branching patterns**: - Through surgical video observation, the most common IMA branching pattern was type 1A (47.0%), followed by type 1B (30.5%), types 2 and 1C accounted for 13.5% and 3.5% respectively, and type 3 (lacking LCA) accounted for 5.5%. - Through 3D - CT vascular reconstruction technology analysis, the proportions of each type were 45.5%, 29.5%, 4.0%, 15.5% and 5.5% respectively. The results of the two methods were similar, with no statistical difference (p = 0.979). 2. **Measurement of IMA length**: - The ranges of IMA length measured by surgical video and 3D - CT vascular reconstruction technology were 1.84 - 6.62 cm and 1.85 - 6.52 cm respectively, and the median values were 3.66 cm and 3.67 cm respectively. - There was a significant difference in the IMA length measured by the two methods (p < 0.001), but the measurement error in most patients was within 0.5 cm, which was considered acceptable. 3. **Positional relationship between LCA and IMV**: - 65.6% of LCAs were located in front of IMV, and 34.4% were located behind IMV. - 57.7% of LCAs traveled medially to IMV, and 42.3% traveled laterally to IMV. ### Conclusion 3D - CT vascular reconstruction technology has high accuracy in predicting the anatomical variations of IMA and its branches, can provide preoperative references for surgeons, shorten the operation time, reduce the occurrence of complications such as bleeding, and ensure the safety of low - level ligation. However, this technology still needs further research and verification, especially in multi - center and long - term follow - up prospective studies.