Rapid point-of-care breath test predicts breast cancer and abnormal mammograms in symptomatic women

Michael Phillips,Therese Bevers,Linda Larsen,Nadine Pappas,Sonali Pathak
DOI: https://doi.org/10.1088/1752-7163/ad7a20
2024-09-14
Journal of Breath Research
Abstract:Background: Previous studies have reported volatile organic compounds (VOCs) in the breath as biomarkers of breast cancer. These biomarkers may be derived from cancer-associated fibroblasts, in which oxidative stress degrades polyunsaturated fatty acids to volatile alkanes and methylated alkane derivatives that are excreted in the breath. We evaluated a rapid point-of-care test for breath VOC biomarkers as predictors of breast cancer and abnormal mammograms. Methods: We studied 593 women aged ≥ 18 yr referred to three sites for mammography for a symptomatic breast-related concern (e.g. breast mass, nipple discharge). A rapid point-of-care breath testing system collected and concentrated alveolar breath VOCs on a sorbent trap and analyzed them with gas chromatography and surface acoustic wave detection in < 6 min. Breath VOC chromatograms were randomly assigned to a training set or to a validation set. Monte Carlo analysis identified significant breath VOC biomarkers of breast cancer and abnormal mammograms in the training set, and these biomarkers were incorporated into a multivariate algorithm to predict disease in the validation set. Results: Prediction of breast cancer: 50 women had biopsy-proven breast cancer (invasive cancer 41, ductal non-invasive cancer 9) Unsplit data set: Breath VOCs identified breast cancer with 83% accuracy (area under curve of receiver operating characteristic), 82% sensitivity and 77.1% specificity. Split data sets: Training set breath VOCs identified breast cancer with 80.3% accuracy, 84% sensitivity and 74.3% specificity. Corresponding values in the validation set were 68%% accuracy, 72.4% sensitivity and 61.5% specificity. Prediction of BIRADS 4 and 5 mammograms (versus BIRADS 1, 2 and 3): Unsplit data set: Breath VOCs identified abnormal mammograms with 76.2% accuracy. Split data sets: Breath VOCs identified abnormal mammograms with 74.2% accuracy, 73.3% sensitivity and 60% specificity. Corresponding values in the validation set were 60.5% accuracy, 64.2% sensitivity and 51% specificity. Conclusions: A rapid point-of-care test for breath VOC biomarkers predicted risk of breast cancer and abnormal mammograms in women with breast-related symptoms.
biochemical research methods,respiratory system
What problem does this paper attempt to address?