Deep Learning Aided Small-Sized Portable Fluorescence Biochip Reader

Ratnesh S. Sengar,Ashutosh K. Upadhyay,Bharti Jain
DOI: https://doi.org/10.1109/tim.2022.3165788
IF: 5.6
2022-01-01
IEEE Transactions on Instrumentation and Measurement
Abstract:We present here the development of a novel fluorescence-based portable biochip reader system, having a novel machine learning method for fluorescence measurement of multianalytes. It is suitable for reading DNA/protein biochips in basic research and clinical diagnosis. We aim to develop a point-of-care diagnostic device in the healthcare sector to accelerate biomedical research at an affordable cost. Innovation is involved in the design of each module of the system that is compact, detachable, and reconfigurable. The system can be used with multiple fluorescent dyes depending on specific requirements. It provides high-sensitivity and high-resolution fluorescent images with lesser scan time compared to currently available state-of-the-art systems. The system is autoaligned/autofocus with a standard microscopic glass slide and custom-developed membrane-based biochip. A new deep learning network Bio-U-Net has been developed for real-time detection and quantification of microarrays. On the real test images, it achieved the precision of 0.9928 and the sensitivity of 0.9698 along with <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="2.903ex" height="2.176ex" style="vertical-align: -0.338ex;" viewBox="0 -791.3 1250 936.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-46" x="0" y="0"></use> <use xlink:href="#MJMAIN-31" x="749" y="0"></use></g></svg></span> -score of 0.9812. The system and deep learning network have been extensively tested and these together provide a low-cost option while maintaining the required accuracy.<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMATHI-46" d="M48 1Q31 1 31 11Q31 13 34 25Q38 41 42 43T65 46Q92 46 125 49Q139 52 144 61Q146 66 215 342T285 622Q285 629 281 629Q273 632 228 634H197Q191 640 191 642T193 659Q197 676 203 680H742Q749 676 749 669Q749 664 736 557T722 447Q720 440 702 440H690Q683 445 683 453Q683 454 686 477T689 530Q689 560 682 579T663 610T626 626T575 633T503 634H480Q398 633 393 631Q388 629 386 623Q385 622 352 492L320 363H375Q378 363 398 363T426 364T448 367T472 374T489 386Q502 398 511 419T524 457T529 475Q532 480 548 480H560Q567 475 567 470Q567 467 536 339T502 207Q500 200 482 200H470Q463 206 463 212Q463 215 468 234T473 274Q473 303 453 310T364 317H309L277 190Q245 66 245 60Q245 46 334 46H359Q365 40 365 39T363 19Q359 6 353 0H336Q295 2 185 2Q120 2 86 2T48 1Z"></path><path stroke-width="1" id="MJMAIN-31" d="M213 578L200 573Q186 568 160 563T102 556H83V602H102Q149 604 189 617T245 641T273 663Q275 666 285 666Q294 666 302 660V361L303 61Q310 54 315 52T339 48T401 46H427V0H416Q395 3 257 3Q121 3 100 0H88V46H114Q136 46 152 46T177 47T193 50T201 52T207 57T213 61V578Z"></path></defs></svg>
engineering, electrical & electronic,instruments & instrumentation
What problem does this paper attempt to address?