Reliability of the Butterfly Test - A Clinical Assessment to Quantify Movement Control of the Cervical Spine

Ziva Majcen Rosker,Izabela Luznik,Jona Sturludottir,Jennifer Stoskus,Jona Olafsdottir
DOI: https://doi.org/10.1016/j.apmr.2024.02.582
IF: 4.06
2024-04-04
Archives of Physical Medicine and Rehabilitation
Abstract:Research Objectives To determine the inter-rater and test-retest reliability of The Butterfly Test, a clinical assessment to quantify movement control of the cervical spine. Design Outcome measure reliability study. Subjects performed The Butterfly Test using the NeckCare System (NeckCare, Iceland). Subjects wore a head-mounted movement sensor and attempted to follow a moving target on a computer screen as accurately as possible with a cursor controlled by the sensor. The target moved at an unpredictable velocity along three predetermined trajectories invisible to the subject. Subjects performed the test twice on the same day, instructed by two raters (A and B), then again two days later (with rater B). Two-way mixed-effects model intraclass correlation coefficient (ICC) for absolute agreement was used to assess inter-rater and test-retest reliability. Setting Laboratory setting. Participants Thirty-five healthy individuals (21 female, 14 male) aged 21-53 years (39 ± 4.8) were recruited using convenience sampling. Interventions Not applicable. Main Outcome Measures Movement control parameters reported by The Butterfly Test were: 1) Amplitude Accuracy (AA), the average distance between the target and subject-controlled cursor; 2) Time-on-Target (ToT), the relative time spent on target; 3) Undershoot (US), the relative time spent behind the target; 4) Overshoot (OS), the relative time spent ahead of the target. Results Good test-retest reliability and moderate to good inter-rater reliability was demonstrated for AA (0.72-0.84). Test-retest and inter-rater reliability was moderate to good for ToT (0.67-0.87), US (0.69-0.77), and OS (0.79-0.87). No consistent differences in ICCs were observed between the three trajectories. Conclusions The Butterfly Test is a reliable clinical tool for assessing movement control of the cervical spine. Reliable objective outcome measures for movement control performance may support clinical decision-making and lead to improved and personalized treatment of cervical spine-related conditions. Author(s) Disclosures Dr. Jona Marin Olafsdottir owns shares in NeckCare.
rehabilitation,sport sciences
What problem does this paper attempt to address?