Effect of end wall boundary layer suction on the performance of high load helium compressor cascade

Yingqi Fan,Zhitao Tian,Jinzhao Zheng,Jianchi Xin,Huawei Lu
DOI: https://doi.org/10.1016/j.pnucene.2024.105116
IF: 2.461
2024-02-18
Progress in Nuclear Energy
Abstract:The high-load design method of helium compressor effectively solves the challenging of helium compression issue in the high-temperature gas-cooled reactor (HTGR). However, this design method also leads to a more significant airflow turning angle in stators of high-load helium compressor, which makes the separation of working fluid in the corner area of the stators become the main factor affecting the operational stability of a high-load helium compressor. By combining numerical simulation with experiment, this paper studies the impact of end wall boundary layer suction on the performance of high-load helium compressor cascades from two aspects: suction position and suction angle. The results show that the suction has significant effects at different angles of attack when the suction position is at the chord length of the blade of 30%. Among them, the improvement effect of the 90° suction scheme is 15.34% at an attack angle of +5° and the improvement effect of the 10° suction scheme is up to 15.63%.
nuclear science & technology
What problem does this paper attempt to address?