Solution-Processable Conductive Composite Hydrogels with Multiple Synergetic Networks toward Wearable Pressure/Strain Sensors

Huige Wei,Deshuo Kong,Tuo Li,Qizhou Xue,Shaoyu Wang,Dapeng Cui,Yudong Huang,Li Wang,Sanming Hu,Tong Wan,Guang Yang
DOI: https://doi.org/10.1021/acssensors.1c00699
IF: 8.9
2021-07-30
ACS Sensors
Abstract:A biocompatible, flexible, yet robust conductive composite hydrogel (CCH) for wearable pressure/strain sensors has been achieved by an all-solution-based approach. The CCH is rationally constructed by in situ polymerization of aniline (An) monomers in the polyvinyl alcohol (PVA) matrix, followed by the cross-linking of PVA with glutaraldehyde (GA) as the cross-linker. The unique multiple synergetic networks in the CCH including strong chemical covalent bonds and abundance of weak physical cross-links, i.e., hydrogen bondings and electrostatic interactions, impart excellent mechanical strength (a fracture tensile strength of 1200 kPa), superior compressibility (ε = 80%@400 kPa), outstanding stretchability (a fracture strain of 670%), high sensitivity (0.62 kPa–1 at a pressure range of 0–1.0 kPa for pressure sensing and a gauge factor of 3.4 at a strain range of 0–300% for strain sensing, respectively), and prominent fatigue resistance (1500 cycling). As the flexible wearable sensor, the CCH is able to monitor different types of human motion and diagnostically distinguish speaking. As a proof of concept, a sensing device has been designed for the real-time detection of 2D distribution of weight or pressure, suggesting its promising potentials for electronic skin, human–machine interaction, and soft robot applications.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acssensors.1c00699.Figures S1–S12: water content test of as-prepared hydrogels; swelling behavior of the CCH; FT-IR spectra of the PVA, PVA/PA, PVA/PA/PANI, and PVA/PA/GA/PANI; stress–strain curves of CCHs with different contents of An; dynamic mechanical analysis of the hydrogels; toughness and elastic modulus of CCHs; processability of hydrogels; cyclic loading–unloading curves of the CCH; experimental setup for sensing performance evaluation; sensitivity of the sensors with different contents of An; relative resistance change–pressure curves of three CCH samples; cells observed by the inverted microscope; Tables S1 and S2: comparison of mechanical performance and electrical conductivity with recent results reported in the literature; a comparison of the sensing performance with recent results reported in the literature (PDF)Compression testing of the CCH (MP4)Stretching process of the CCH (MP4)Resistance change in the reversible compressing shown via an LED indicator (MP4)Resistance change of the reversible stretching shown via an LED indicator (MP4)Visualization of the resistance change on the same position of the checkboard device (MP4)Visualization of the resistance change on the different position of the checkboard device (MP4)This article has not yet been cited by other publications.
chemistry, multidisciplinary, analytical,nanoscience & nanotechnology
What problem does this paper attempt to address?