Influence of formulation and preparation process on ambroxol hydrochloride dry powder inhalation characteristics and aerosolization properties

Yachao Ren,Chaoqun Yu,Kangkang Meng,Xing Tang
DOI: https://doi.org/10.1080/03639040802154913
Abstract:The objective of this study is to evaluate the influence of formulation and preparation process on ambroxol hydrochloride (AH) dry powder inhalation (DPI) characteristics and aerosolization properties. Spray-dried samples of AH, AH/leucine, and AH/leucine/mannitol were prepared from their corresponding water solutions under the same conditions to study the influence of the composition, and the AH/leucine/mannitol (2.5/0.5/1 by weight) formulation was used for investigation of the effect of the preparation process. Following spray-drying, the resulting powders were characterized using scanning electron microscopy, laser diffraction, tapped density, and angle of repose measurements, and the aerosolization performance was determined using a twin-stage liquid impinger. AH/leucine/mannitol (2.5/0.5/1 by weight) obtained by cospray-drying improved the AH aerosolization properties. The AH/leucine/mannitol (2.5/0.5/1 by weight) preparation exhibited the following properties: 62.34% yield, 0.34 g/cm(3) tap density, 2.71 microm d(ae), 33.45 degrees angle of repose, and 30.93% respirable fraction. The influence of the preparation process on DPI characteristics and aerosolization properties was relatively small, but the influence of the composition was relatively large. Optimization of DPI can be achieved by selecting the most appropriate formulation and preparation process.
What problem does this paper attempt to address?