Antibacterial activities of titanium dioxide (TiO2) nanotube with planar titanium silver (TiAg) to prevent orthopedic implant infection

Lihong Zhang,Zhihui Jin
DOI: https://doi.org/10.1186/s13018-024-04596-0
IF: 2.6
2024-02-18
Journal of Orthopaedic Surgery and Research
Abstract:Orthopedic implant infection has become a common catastrophic complication after various orthopedic implants, which can lead to prolonged use of antibiotics and even surgical failure. The quality of care (QoC) of orthopedic implant infection is very important.
orthopedics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: how to effectively prevent and reduce orthopedic implant infections. Specifically, the researchers prepared titanium dioxide (TiO₂) nanotube arrays and planar titanium - silver (TiAg) composites and tested their antibacterial properties, hoping to find a more effective antibacterial material to prevent orthopedic implant infections. ### Background and Problem Description Orthopedic implant infection is a common and catastrophic complication, which may lead to prolonged antibiotic use and even surgical failure. With the wide application of orthopedic surgery, the implant surface is likely to become a basis for bacterial adhesion, increasing the risk of infection. In addition, the surgery itself may cause tissue damage and trauma, providing a way for bacteria to invade. Therefore, developing implant coatings with antibacterial properties and new anti - infection strategies are crucial for reducing the risk of infection. ### Research Methods To verify the antibacterial effects of TiO₂ nanotube arrays and planar TiAg, the researchers conducted the following experiments: 1. **Patient Selection**: - Four hundred patients hospitalized in the orthopedics department of Wuhan Fourth Hospital from May 2019 to May 2020 were selected as the control group. - Four hundred patients hospitalized from June 2020 to June 2021 were selected as the observation group. 2. **Material Preparation**: - TiO₂ nanotube arrays and planar TiAg composites were prepared. - A pure iron film was used as the control group. 3. **Antibacterial Property Testing**: - The antibacterial rates of TiO₂ nanotube arrays and planar TiAg against Staphylococcus aureus and Escherichia coli were tested by the plate count method and fluorescence staining method. ### Main Results 1. **Antibacterial Rate**: - For Staphylococcus aureus, the antibacterial rates of TiO₂ nanotube arrays and planar TiAg on the 10th and 20th days were significantly higher than those of the pure iron film (P < 0.05). - For Escherichia coli, the antibacterial rates of TiO₂ nanotube arrays and planar TiAg on the 10th and 20th days were also significantly higher than those of the pure iron film (P < 0.05). 2. **Quality Assessment**: - The accuracy of the observation group in hospitalization assessment, disease assessment, adverse event intervention, nursing record archiving, and nursing satisfaction was significantly higher than that of the control group (P < 0.05). ### Conclusion The research results show that TiO₂ nanotube arrays and planar TiAg have good antibacterial properties and can effectively prevent orthopedic implant infections. At the same time, establishing an orthopedic - specific quality of care (QoC) evaluation system can significantly improve the quality of orthopedic nursing. ### Keywords - TiO₂ nanotubes - Orthopedic implant infection - Orthopedic - specific QoC - Planar TiAg - Antibacterial property Through the above research, the author aims to provide new ideas and methods for improving the antibacterial properties of orthopedic implants, thereby improving the treatment effect and quality of life of patients.