High‐level feature‐guided attention optimized neural network for neonatal lateral ventricular dilatation prediction

Yulin Peng,Dongmei Liu,Ying Deng,Meixiang Zhang,Lingyu Yan,Yingchun Luo,Junyi Yan
DOI: https://doi.org/10.1002/mp.17375
IF: 4.506
2024-08-30
Medical Physics
Abstract:Background Periventricular‐intraventricular hemorrhage can lead to posthemorrhagic ventricular dilatation or even posthemorrhagic hydrocephalus if not detected promptly. Sequential cranial ultrasound scans are typically used for their diagnoses. Nonetheless, manual image audit has numerous disadvantages. Purpose This study aimed to develop a predictive model utilizing modified inception (MI) and high‐level feature‐guided attention (HFA) modules for predicting neonatal lateral ventricular dilation via ultrasound images. Methods The MI modules reduced input data sizes and dimensions, while the HFA modules effectively delved into semantic information through supervision from high‐level feature images to low‐level feature images. The process facilitated the accurate identification of dilated lateral ventricles. A total of 710 neonates, corresponding to 1420 lateral ventricles, were recruited in this study. Each lateral ventricle was captured in two images, one on the parasagittal plane and the other on the coronal plane. The combination of anterior horn width, ventricular index, thalamo‐occipital distance, and ventricular height served as the gold standard. A lateral ventricle would be considered dilatated if any of these four indices exceeded its upper reference value. These lateral ventricles were randomly split into training and testing sets at a 7:3 ratio. We evaluated the validity of our proposed approach and its competitors across the coronal plane, parasagittal plane, and overall performance. We also determined the impact of subjects' baseline characteristics on the overall performance of the proposed approach. Additionally, ablation analyses were conducted to ensure the efficacy of the proposed approach. Results Our proposed approach achieved the largest Youden index (0.65, 95% CI: 0.58–0.72), DOR (27.11, 95% CI: 15.89–46.26), area under curves (AUC) of receiver operating characteristic curve (ROC) (0.84, 95% CI: 0.80–0.88), and AUC of precision‐recall curve (PRC) (0.81, 95% CI: 0.74–0.86) in the overall performance assessment and ablation analyses. Moreover, it boasted the biggest Cramer's V values on the coronal (Cramer's V = 0.488, p
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?